The evaluation of the flow re-direction endoluminal device (FRED) for the treatment of selected intracranial aneurysms: a Polish multicenter study

This Polish multicenter study aims to evaluate the effectiveness and safety of the Flow Direction Endoluminal Device (FRED) in treating selected unruptured intracranial aneurysms. The FRED Poland Study was an observational, multicenter, prospective study conducted in 8 Polish investigational sites. Imaging results were independently assessed by a Corelab and adverse events were adjudicated by a Clinical Events Committee (CEC). Clinical results up to 24 months and anatomical results at 6-, 12- and 24-months post-treatment were reported. A total of 86 patients with 89 target aneurysms were enrolled between January 2016 and September 2017. Most aneurysms were located on the anterior circulation (93.2%, 83/89 aneurysms) with the majority (64.0%, 57/89) being small (< 10 mm) in size. Treatment was successfully performed in 86 out of 89 cases (96.6%). The permanent neurological morbidity rate was 3.6%, and the neurological mortality rate was 2.4%. Imaging follow-up at 6 months showed complete occlusion of the aneurysm in 64.9% of cases, increasing to 79.5% at 12 months and 85.5% at 24 months. This study offers a comprehensive overview of the flow diversion treatment approach, demonstrating that the FRED device is effective and safe for use in intracranial aneurysm treatment. These results align with existing literature, reaffirming the device reliability and suitability for clinical use.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-02-21
DOI
https://doi.org/10.1038/s41598-025-90463-9
Citations
1
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The evaluation of the flow re-direction endoluminal device (FRED) for the treatment of selected intracranial aneurysms: a Polish multicenter study

Katarzyna Lubkowska, Remigiusz Krysiak, Mariusz Banach, Mateusz Pinkiewicz et al.
1 citations
Scientific Reports
Intracranial Aneurysms: Treatment and Complications
1.39
article

The evaluation of the flow re-direction endoluminal device (FRED) for the treatment of selected intracranial aneurysms: a Polish multicenter study

Katarzyna Lubkowska, Remigiusz Krysiak, Mariusz Banach, Mateusz Pinkiewicz, Wojciech Poncyljusz, Edoardo Boccardi, Miłosz Zbroszczyk, Tadeusz Jan Popiela, Jarosław Wrzyszcz, Michel Piotin, Sławomir Bereza, Michał Zawadzki, Maciej Szajner, Jarosław Żyłkowski, Kamila Smulska, Christophe Cognard, Raphaël Blanc, Błażej Nowak, Maciej Jaworski, Paweł Brzegowy, Katarzyna Mokrzycka, Ewa Horoch-Łyszczarek
article en
1 citations

Abstract

This Polish multicenter study aims to evaluate the effectiveness and safety of the Flow Direction Endoluminal Device (FRED) in treating selected unruptured intracranial aneurysms. The FRED Poland Study was an observational, multicenter, prospective study conducted in 8 Polish investigational sites. Imaging results were independently assessed by a Corelab and adverse events were adjudicated by a Clinical Events Committee (CEC). Clinical results up to 24 months and anatomical results at 6-, 12- and 24-months post-treatment were reported. A total of 86 patients with 89 target aneurysms were enrolled between January 2016 and September 2017. Most aneurysms were located on the anterior circulation (93.2%, 83/89 aneurysms) with the majority (64.0%, 57/89) being small (< 10 mm) in size. Treatment was successfully performed in 86 out of 89 cases (96.6%). The permanent neurological morbidity rate was 3.6%, and the neurological mortality rate was 2.4%. Imaging follow-up at 6 months showed complete occlusion of the aneurysm in 64.9% of cases, increasing to 79.5% at 12 months and 85.5% at 24 months. This study offers a comprehensive overview of the flow diversion treatment approach, demonstrating that the FRED device is effective and safe for use in intracranial aneurysm treatment. These results align with existing literature, reaffirming the device reliability and suitability for clinical use.

Scientific ReportsVol. 15(1)
Medical University of Lublin (PL), Jagiellonian University (PL), Medical University of Silesia (PL), Medical University of Warsaw (PL), Azienda Socio Sanitaria Territoriale Grande Ospedale Metropolitano Niguarda (IT), Medical University of Lodz (PL), Fondation de Rothschild (FR), Ministry of Interior and Administration (PL), Hôpital Purpan (FR), Central Clinical Hospital (PL), Pomeranian Medical University (PL)
Openalex Percentile: Top 23%
Intracranial Aneurysms: Treatment and Complications
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.