Infectious cough droplet dynamics in a makeshift hospital isolation ward

The COVID-19 pandemic highlighted the need for rapidly deployable healthcare facilities, leading to increased use of modular construction methods. Nonetheless, knowledge about airflow patterns and the spread of bioaerosols in these wards remains insufficient, potentially heightening the risk of cross-infection among healthcare workers and patients. This paper presents a ventilation design for a modular negative-pressure ward aimed at reducing the spread of infectious particles. We investigate the effects of various ventilation designs, patient postures (sitting and supine), and air changes per hour (ACH) on the spread of infectious cough droplets in an airborne infection isolation room using large eddy simulation and the Eulerian–Lagrangian model. Findings show that ceiling exhaust grilles (design 2) resulted in the lowest radial dispersion (3.64 m) at 12 ACH, while sidewall exhausts (baseline) performed best at higher ACH levels. Seated patients had quicker droplet evaporation compared to those in a supine position. The best setups for reducing droplet survival included exhaust grilles at the bed's bottom and ceiling, maintaining a minimum of 12 ACH. Cases 5 and 13, with grilles over the patient's head and at the bed's bottom, showed the lowest concentrations of DPM, under 0.008 km−3 near the source and less than 0.001 km−3 mid-room. Sitting posture consistently led to lower DPM concentrations. This research emphasizes the critical role of exhaust placement in reducing droplet re-circulation and transmission risks, ultimately contributing to improved ventilation strategies and infection control in AII rooms.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2025-02-01
DOI
https://doi.org/10.1063/5.0254401
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Infectious cough droplet dynamics in a makeshift hospital isolation ward

Hai-Tao Yu, Leslie Kojo Norvihoho, Bin Chen, Jing Yin et al.
Physics of Fluids
Infection Control and Ventilation
article

Infectious cough droplet dynamics in a makeshift hospital isolation ward

Hai-Tao Yu, Leslie Kojo Norvihoho, Bin Chen, Jing Yin, Zhifu Zhou, Yi Liu, Qi-Di Wang, Xin-Gang Zhu
article en

Abstract

The COVID-19 pandemic highlighted the need for rapidly deployable healthcare facilities, leading to increased use of modular construction methods. Nonetheless, knowledge about airflow patterns and the spread of bioaerosols in these wards remains insufficient, potentially heightening the risk of cross-infection among healthcare workers and patients. This paper presents a ventilation design for a modular negative-pressure ward aimed at reducing the spread of infectious particles. We investigate the effects of various ventilation designs, patient postures (sitting and supine), and air changes per hour (ACH) on the spread of infectious cough droplets in an airborne infection isolation room using large eddy simulation and the Eulerian–Lagrangian model. Findings show that ceiling exhaust grilles (design 2) resulted in the lowest radial dispersion (3.64 m) at 12 ACH, while sidewall exhausts (baseline) performed best at higher ACH levels. Seated patients had quicker droplet evaporation compared to those in a supine position. The best setups for reducing droplet survival included exhaust grilles at the bed's bottom and ceiling, maintaining a minimum of 12 ACH. Cases 5 and 13, with grilles over the patient's head and at the bed's bottom, showed the lowest concentrations of DPM, under 0.008 km−3 near the source and less than 0.001 km−3 mid-room. Sitting posture consistently led to lower DPM concentrations. This research emphasizes the critical role of exhaust placement in reducing droplet re-circulation and transmission risks, ultimately contributing to improved ventilation strategies and infection control in AII rooms.

Physics of FluidsVol. 37(2)
China General Nuclear Power Corporation (China) (CN), Xi'an Jiaotong University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 95%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.