A partial-thickness ‘scleral belt loop’ for MicroShunt implant

The purpose of this article is to introduce a new surgical technique for the PreserFloTM MicroShunt implant. This technique involves creating a partial-thickness scleral belt loop before repositioning the Tenon's capsule and the conjunctiva toward the limbus. The distal end of the device is passed under the lamellar belt of the sclera, but the tip remains open and not covered by the loop. With this surgical technique, the MicroShunt adheres perfectly to the scleral profile of all eyes. As a result, the device's end tip does not stress the Tenon's/conjunctival flap during postoperative eye movements, thereby minimizing conjunctival erosion and inflammation. This method is efficient, requiring very short additional time. Consequently, it can be seamlessly integrated into the standard MicroShunt implant procedure without incurring extra costs, ultimately trying to reduce the need for surgical revisions of the filtration bleb.

Authors

Institutions

Publication Details

Journal
Indian Journal of Ophthalmology
Published
2025-02-21
DOI
https://doi.org/10.4103/ijo.ijo_1212_24
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A partial-thickness ‘scleral belt loop’ for MicroShunt implant

Francesco Sartini, Martina Menchini, Chiara Posarelli, Michele Figus et al.
Indian Journal of Ophthalmology
Glaucoma and retinal disorders
article

A partial-thickness ‘scleral belt loop’ for MicroShunt implant

Francesco Sartini, Martina Menchini, Chiara Posarelli, Michele Figus, Giamberto Casini, Gianluca Guidi
article en

Abstract

The purpose of this article is to introduce a new surgical technique for the PreserFloTM MicroShunt implant. This technique involves creating a partial-thickness scleral belt loop before repositioning the Tenon's capsule and the conjunctiva toward the limbus. The distal end of the device is passed under the lamellar belt of the sclera, but the tip remains open and not covered by the loop. With this surgical technique, the MicroShunt adheres perfectly to the scleral profile of all eyes. As a result, the device's end tip does not stress the Tenon's/conjunctival flap during postoperative eye movements, thereby minimizing conjunctival erosion and inflammation. This method is efficient, requiring very short additional time. Consequently, it can be seamlessly integrated into the standard MicroShunt implant procedure without incurring extra costs, ultimately trying to reduce the need for surgical revisions of the filtration bleb.

Indian Journal of OphthalmologyVol. 73(Suppl 2)
University of Pisa (IT), Azienda Ospedaliera Universitaria Pisana (IT)
Life below water
Openalex Percentile: Top 94%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.