Reduced Heating Wireless Energy Transmission System for Powering Implanted Circulatory Assist Devices: Benchtop and In-Vivo Studies

This study aimed to develop a novel Transdermal Energy Transmission System (TETS) device that addresses the driveline complications faced by patients with advanced heart failure (HF). Our TETS device utilizes a two-channel configuration with a very-low duty cycle and a pulsed RF power transmission technique, along with elliptically shaped flexible coil inductive coupling elements. We integrated a battery charging controller module into the TETS, enabling it to recharge an implanted Lithium-Ion (Li-Ion) battery that powers low-power-rated Circulatory Assist Devices, or left ventricular assist devices (LVADs). Benchtop measurements demonstrated that the TETS delivered energy from the implanted coils to the battery charging module, at a charging rate of up to 2900 J/h, presented an average temperature increase (ΔT) of 3 °C. We conducted in vivo measurements using four porcine models followed by histopathological analysis of the skin tissue in the implanted coils areas. The thermal profile analysis from the in vivo measurements and the calculated charging rates from the current and voltage waveforms, in porcine models, indicated that the charging rate and temperature varied for each model. The maximum energy charging rate observed was 2200 J/h, with an average ΔT of 3 °C. The exposed skin tissue histopathological analysis results showed no evidence of tissue thermal damage in the in vivo measurements. These results demonstrate the feasibility of our developed TETS device for wireless driving implanted low-power-rated LVADs and Li-Ion charging.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-02-21
DOI
https://doi.org/10.3390/s25051311
Citations
1
Primary Topic
Wireless Power Transfer Systems
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reduced Heating Wireless Energy Transmission System for Powering Implanted Circulatory Assist Devices: Benchtop and In-Vivo Studies

Omar Escalona, Antonio M. Bosnjak, Paul Crawford, Howard Larkin et al.
1 citations
Sensors
Wireless Power Transfer Systems
0.73
article

Reduced Heating Wireless Energy Transmission System for Powering Implanted Circulatory Assist Devices: Benchtop and In-Vivo Studies

Omar Escalona, Antonio M. Bosnjak, Paul Crawford, Howard Larkin, Robin W. Grimes, James McLaughlin, David McEneaney, Mohammad L. Karim
article en
1 citations

Abstract

This study aimed to develop a novel Transdermal Energy Transmission System (TETS) device that addresses the driveline complications faced by patients with advanced heart failure (HF). Our TETS device utilizes a two-channel configuration with a very-low duty cycle and a pulsed RF power transmission technique, along with elliptically shaped flexible coil inductive coupling elements. We integrated a battery charging controller module into the TETS, enabling it to recharge an implanted Lithium-Ion (Li-Ion) battery that powers low-power-rated Circulatory Assist Devices, or left ventricular assist devices (LVADs). Benchtop measurements demonstrated that the TETS delivered energy from the implanted coils to the battery charging module, at a charging rate of up to 2900 J/h, presented an average temperature increase (ΔT) of 3 °C. We conducted in vivo measurements using four porcine models followed by histopathological analysis of the skin tissue in the implanted coils areas. The thermal profile analysis from the in vivo measurements and the calculated charging rates from the current and voltage waveforms, in porcine models, indicated that the charging rate and temperature varied for each model. The maximum energy charging rate observed was 2200 J/h, with an average ΔT of 3 °C. The exposed skin tissue histopathological analysis results showed no evidence of tissue thermal damage in the in vivo measurements. These results demonstrate the feasibility of our developed TETS device for wireless driving implanted low-power-rated LVADs and Li-Ion charging.

SensorsVol. 25(5)
University of Ulster (GB), Craigavon Area Hospital (GB)
Government of the United Kingdom, UK Research and Innovation, Innovate UK
Affordable and clean energy
Openalex Percentile: Top 31%
Wireless Power Transfer Systems
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.