Heterogeneity of ventricular action potentials in neonatal rat cardiomyocytes and methodological aspects of patch clamp measurements

Measurement of the ventricular action potential (AP) via whole-cell patch clamp is an important contributor to cardiac electrophysiological research. Neonatal rat ventricular cardiomyocytes (NRVCM) are a commonly used model, in particular for stressor- or drug-related questions. High variability of APs and individual methodological settings hinder comparison both in individual studies and, to an even greater degree, between different projects. This study aims to describe sources of AP heterogeneity in NRVCM related to patch clamp measurement with a focus on resolvable causes. Therefore, AP of NRVCM were induced in whole-cell configuration and measured in current-clamp mode. The effects of varying setup temperature, electrode resistance, resting- (RMP), respectively holding membrane potential (HMP), induction approach, current pulse duration and amplitude plus total assay duration were studied and compared to systematically analyzed literature. We analyzed the impact on different output parameters, namely, maximal upstroke velocity (dV/dt), maximal AP amplitude (APA) and AP duration at different percentages (XX%) of repolarization, APD<sub>XX</sub>. In a comparative literature research, we found that mean APD<sub>90</sub> in between 27.0 and 560.7 ms (own data 59.7 ± 5.8 ms) were described, with high variability and likely non-Gaussian distribution. In this study, APD<sub>90</sub>, APD<sub>50</sub> and APD<sub>30</sub>, are decreased at more negative RMP (respectively HMP) values. E.g., APD<sub>90</sub> is shortened by ∼60% after lowering HMP from -70 mV to -90 mV) while dV/dt and APA are increased at a more negative HMP. Pulse duration in induction did not affect main AP parameters itself, but induction energy levels above 1.5-fold the threshold energy level increased APA, while APD<sub>50</sub> and APD<sub>90</sub> were shortened. During series of APs at 1 Hz, spike duration (APD<sub>90</sub>) decreased by ∼27%, with stable AP after the third repetitive AP. Spike duration did also decreased by ∼40% after prolongated measurements for 21 min, indicating degradation of electrophysiological properties. To improve data quality in NRVCM-APs, we suggest using a constant HMP, adjustment of current pulse amplitude to the individual cells' threshold and the use of repetitive AP-inductions. Finally, we suggest the use of nonparametric statistical methods for statistical analysis. These aspects could reduce variability and lead to more reliable and comparable data.

Authors

Institutions

Publication Details

Journal
Frontiers in Physiology
Published
2025-02-21
DOI
https://doi.org/10.3389/fphys.2025.1537345
Citations
3
Primary Topic
Cardiac electrophysiology and arrhythmias
Type
article
Field-Weighted Citation Impact
4.16

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heterogeneity of ventricular action potentials in neonatal rat cardiomyocytes and methodological aspects of patch clamp measurements

Norbert Frey, Dierk Thomas, Pascal Syren, Axel Schöffel et al.
3 citations
Frontiers in Physiology
Cardiac electrophysiology and arrhythmias
4.16
article

Heterogeneity of ventricular action potentials in neonatal rat cardiomyocytes and methodological aspects of patch clamp measurements

Norbert Frey, Dierk Thomas, Pascal Syren, Axel Schöffel, Patrick Lugenbiel, Chiara Heß, Claus Bruehl, Anna Zlatopolskaia, Teresa Caspari
article en
3 citations

Abstract

Measurement of the ventricular action potential (AP) via whole-cell patch clamp is an important contributor to cardiac electrophysiological research. Neonatal rat ventricular cardiomyocytes (NRVCM) are a commonly used model, in particular for stressor- or drug-related questions. High variability of APs and individual methodological settings hinder comparison both in individual studies and, to an even greater degree, between different projects. This study aims to describe sources of AP heterogeneity in NRVCM related to patch clamp measurement with a focus on resolvable causes. Therefore, AP of NRVCM were induced in whole-cell configuration and measured in current-clamp mode. The effects of varying setup temperature, electrode resistance, resting- (RMP), respectively holding membrane potential (HMP), induction approach, current pulse duration and amplitude plus total assay duration were studied and compared to systematically analyzed literature. We analyzed the impact on different output parameters, namely, maximal upstroke velocity (dV/dt), maximal AP amplitude (APA) and AP duration at different percentages (XX%) of repolarization, APD<sub>XX</sub>. In a comparative literature research, we found that mean APD<sub>90</sub> in between 27.0 and 560.7 ms (own data 59.7 ± 5.8 ms) were described, with high variability and likely non-Gaussian distribution. In this study, APD<sub>90</sub>, APD<sub>50</sub> and APD<sub>30</sub>, are decreased at more negative RMP (respectively HMP) values. E.g., APD<sub>90</sub> is shortened by ∼60% after lowering HMP from -70 mV to -90 mV) while dV/dt and APA are increased at a more negative HMP. Pulse duration in induction did not affect main AP parameters itself, but induction energy levels above 1.5-fold the threshold energy level increased APA, while APD<sub>50</sub> and APD<sub>90</sub> were shortened. During series of APs at 1 Hz, spike duration (APD<sub>90</sub>) decreased by ∼27%, with stable AP after the third repetitive AP. Spike duration did also decreased by ∼40% after prolongated measurements for 21 min, indicating degradation of electrophysiological properties. To improve data quality in NRVCM-APs, we suggest using a constant HMP, adjustment of current pulse amplitude to the individual cells' threshold and the use of repetitive AP-inductions. Finally, we suggest the use of nonparametric statistical methods for statistical analysis. These aspects could reduce variability and lead to more reliable and comparable data.

Frontiers in PhysiologyVol. 16
Heidelberg University (DE), University Hospital Heidelberg (DE), German Centre for Cardiovascular Research (DE)
Bristol-Myers Squibb, Pfizer, AstraZeneca, Sanofi, Boston Scientific Corporation, ZOLL Medical Corporation, Bayer Vital, Biosense Webster, Daiichi Sankyo Europe
Affordable and clean energy
Openalex Percentile: Top 7%
Cardiac electrophysiology and arrhythmias
4.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.