IoT-Based System Using IMU Sensor Fusion for Knee Telerehabilitation Monitoring

High costs and clinical limitations restrict access to rehabilitation services, especially in low- and middle-income countries. There is a growing need for affordable, home-based solutions that enable continuous remote monitoring of patient rehabilitation progress. This work proposes an Internet of Thing (IoT)-based system for knee movement monitoring during telerehabilitation. The system comprises wearable inertial measurement units (IMUs) integrated into an IoT architecture. This architecture leverages edge and cloud computing to facilitate remote monitoring and real-time feedback. A sensor fusion algorithm was implemented on the edge to estimate knee joint angle, and a cloud-based application was developed to extract kinematic parameters and assess rehabilitation outcomes. The system was implemented using system-on-chip (SoC) technology, allowing embedded signal processing and wireless communication in a compact and low-power design. Three experimental validation tests were conducted: One hardware test evaluating the performance of the proposed sensor fusion algorithm; goniometer-based static test assessing the impact of environmental interference on system accuracy; dynamic test involving rehabilitation exercises to validate system performance against a gold-standard video-based system in the home context. The results demonstrated that the proposed algorithm achieved an optimal trade-off between accuracy, computational efficiency, and resilience to magnetic distortions. The system showed acceptable accuracy, with an average root mean square error (RMSE) ranging from 3.08° to 6.43° across all exercises. These results are consistent with the current state of the art, highlighting the system’s potential for objective and remote monitoring of knee movement in home-based rehabilitation.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-02-21
DOI
https://doi.org/10.1109/jsen.2025.3542261
Citations
3
Primary Topic
Advanced Computing and Algorithms
Type
article
Field-Weighted Citation Impact
18.53
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

IoT-Based System Using IMU Sensor Fusion for Knee Telerehabilitation Monitoring

Abdelilah Jilbab, Abdelouahad Achmamad, Atman Jbari, Mohamed El Fezazi
3 citations
IEEE Sensors Journal
Advanced Computing and Algorithms
18.53
article

IoT-Based System Using IMU Sensor Fusion for Knee Telerehabilitation Monitoring

Abdelilah Jilbab, Abdelouahad Achmamad, Atman Jbari, Mohamed El Fezazi
article en
3 citations

Abstract

High costs and clinical limitations restrict access to rehabilitation services, especially in low- and middle-income countries. There is a growing need for affordable, home-based solutions that enable continuous remote monitoring of patient rehabilitation progress. This work proposes an Internet of Thing (IoT)-based system for knee movement monitoring during telerehabilitation. The system comprises wearable inertial measurement units (IMUs) integrated into an IoT architecture. This architecture leverages edge and cloud computing to facilitate remote monitoring and real-time feedback. A sensor fusion algorithm was implemented on the edge to estimate knee joint angle, and a cloud-based application was developed to extract kinematic parameters and assess rehabilitation outcomes. The system was implemented using system-on-chip (SoC) technology, allowing embedded signal processing and wireless communication in a compact and low-power design. Three experimental validation tests were conducted: One hardware test evaluating the performance of the proposed sensor fusion algorithm; goniometer-based static test assessing the impact of environmental interference on system accuracy; dynamic test involving rehabilitation exercises to validate system performance against a gold-standard video-based system in the home context. The results demonstrated that the proposed algorithm achieved an optimal trade-off between accuracy, computational efficiency, and resilience to magnetic distortions. The system showed acceptable accuracy, with an average root mean square error (RMSE) ranging from 3.08° to 6.43° across all exercises. These results are consistent with the current state of the art, highlighting the system’s potential for objective and remote monitoring of knee movement in home-based rehabilitation.

IEEE Sensors JournalVol. 25(7)
Mohammed V University (MA)
Openalex Percentile: Top 1%
Advanced Computing and Algorithms
18.53
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

IoT-Based System Using IMU Sensor Fusion for Knee Telerehabilitation Monitoring — Abdelilah Jilbab, Abdelouahad Achmamad, et al. · IEEE Sensors Journal (2025) | TGRS Research Map | TGRS