Necessity of removal of high-intensity non-speckle signals in Nakagami-based ultrasound tissue characterization under pre-Rayleigh condition

Abstract Envelope statistics are one of the powerful indicators for ultrasound-based tissue characterization. In this study, the effect of non-speckle (NS) signals on Nakagami-based tissue characterization under the pre-Rayleigh condition was evaluated, and removal methods previously proposed for multi-Rayleigh-based signals were extended to apply to Nakagami-based signals. Ultrasonic simulation using Field II confirmed that NS signals possibly induced the underestimation of Nakagami shape parameter with an error of several tens of percent. The NS removal method enabled the great suppression of estimation error below the error of several percents in most cases. Furthermore, the method could suppress the estimation error below the statistical variance of Nakagami shape-parameter estimation. These results indicated the necessity of NS removal for accurate Nakagami-based tissue characterization. As Nakagami-based tissue characterization has the potential applicability to several diseases, the results in this study will contribute to the development of diagnostic methods for diseases.

Authors

Institutions

Publication Details

Journal
Japanese Journal of Applied Physics
Published
2025-02-21
DOI
https://doi.org/10.35848/1347-4065/adb8f5
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Necessity of removal of high-intensity non-speckle signals in Nakagami-based ultrasound tissue characterization under pre-Rayleigh condition

Shin Yoshizawa, Shohei Mori
Japanese Journal of Applied Physics
Ultrasound Imaging and Elastography
article

Necessity of removal of high-intensity non-speckle signals in Nakagami-based ultrasound tissue characterization under pre-Rayleigh condition

Shin Yoshizawa, Shohei Mori
article en

Abstract

Abstract Envelope statistics are one of the powerful indicators for ultrasound-based tissue characterization. In this study, the effect of non-speckle (NS) signals on Nakagami-based tissue characterization under the pre-Rayleigh condition was evaluated, and removal methods previously proposed for multi-Rayleigh-based signals were extended to apply to Nakagami-based signals. Ultrasonic simulation using Field II confirmed that NS signals possibly induced the underestimation of Nakagami shape parameter with an error of several tens of percent. The NS removal method enabled the great suppression of estimation error below the error of several percents in most cases. Furthermore, the method could suppress the estimation error below the statistical variance of Nakagami shape-parameter estimation. These results indicated the necessity of NS removal for accurate Nakagami-based tissue characterization. As Nakagami-based tissue characterization has the potential applicability to several diseases, the results in this study will contribute to the development of diagnostic methods for diseases.

Japanese Journal of Applied PhysicsVol. 64(3)
Tohoku University (JP)
Openalex Percentile: Top 95%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Necessity of removal of high-intensity non-speckle signals in Nakagami-based ultrasound tissue characterization under pre-Rayleigh condition — Shin Yoshizawa, Shohei Mori · Japanese Journal of Applied Physics (2025) | TGRS Research Map | TGRS