Electrochemical Non-Enzymatic Biosensing of Cortisol Using ZnO-Graphene Nanocomposite

Cortisol is a key factor in developmental and behavioural research, measured widely in blood, urine, and saliva. Electrochemical sensing has emerged as a reliable technique in the development of point-of-care devices for detecting cortisol. Here, a ZnO/Graphene coated graphite was used as a sensing electrode for the detection of cortisol. The performance of the sensing electrode was tested in the presence of cortisol using electrochemical techniques and the impact of scan rate, concentration, cycle numbers, linear range, and limit of detection is reported. The fabricated ZnO/Graphene/PGE sensing electrode demonstrated excellent performance for cortisol detection, exhibiting a linear response over a wide concentration range of 10.874 to 173.981 mg ml −1 and a low limit of detection of 6.162 μg ml −1 . Additionally, the sensor displayed high stability over 60 days, with good repeatability and reproducibility. This shows that the ZnO/Graphene nanocomposite can be used as a non-enzymatic sensor providing a more reliable and effective cortisol sensing.

Authors

Publication Details

Journal
Journal of The Electrochemical Society
Published
2025-02-21
DOI
https://doi.org/10.1149/1945-7111/adb912
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical Non-Enzymatic Biosensing of Cortisol Using ZnO-Graphene Nanocomposite

D. Durgalakshmi, Ajay Rakkesh Rajendran, Harini Loganathan
1 citations
Journal of The Electrochemical Society
Electrochemical sensors and biosensors
0.73
article

Electrochemical Non-Enzymatic Biosensing of Cortisol Using ZnO-Graphene Nanocomposite

D. Durgalakshmi, Ajay Rakkesh Rajendran, Harini Loganathan
article en
1 citations

Abstract

Cortisol is a key factor in developmental and behavioural research, measured widely in blood, urine, and saliva. Electrochemical sensing has emerged as a reliable technique in the development of point-of-care devices for detecting cortisol. Here, a ZnO/Graphene coated graphite was used as a sensing electrode for the detection of cortisol. The performance of the sensing electrode was tested in the presence of cortisol using electrochemical techniques and the impact of scan rate, concentration, cycle numbers, linear range, and limit of detection is reported. The fabricated ZnO/Graphene/PGE sensing electrode demonstrated excellent performance for cortisol detection, exhibiting a linear response over a wide concentration range of 10.874 to 173.981 mg ml −1 and a low limit of detection of 6.162 μg ml −1 . Additionally, the sensor displayed high stability over 60 days, with good repeatability and reproducibility. This shows that the ZnO/Graphene nanocomposite can be used as a non-enzymatic sensor providing a more reliable and effective cortisol sensing.

Journal of The Electrochemical SocietyVol. 172(3)
Openalex Percentile: Top 31%
Electrochemical sensors and biosensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Electrochemical Non-Enzymatic Biosensing of Cortisol Using ZnO-Graphene Nanocomposite — D. Durgalakshmi, Ajay Rakkesh Rajendran, et al. · Journal of The Electrochemical Society (2025) | TGRS Research Map | TGRS