Development of magnetite modified graphite electrode: Application in electro-Fenton process for degradation of antidiabetic drug metformin hycloridate

• Degradation of metformin by the electro-Fenton process in aqueous and synthetic matrix. • Electrocatalytic improvement of graphite electrode from magnetite impregnation. • Monitoring of electrogenerated oxidizing agents in the electro-Fenton process. • The kinetic evolution of degradation was represented by the pseudo-first order model. • Lower ecotoxicological effect after metformin treatment in aqueous solution. Metformin hydrochloride (CMTF) is a widely used antidiabetic medication. However, the increase in its consumption combined with the fact that only 10 % of the drug is metabolized by the body, can promote contamination of the aquatic environment. Thus, the objective of the work was to develop a modified graphite electrode impregnated with magnetite, not yet reported in the literature, and apply it in the treatment of the drug CMTF via electro-Fenton. The higher degradation percentage obtained for the aqueous solution (AS) was 83.55 %. The developed electrode was applied in the treatment of synthetic effluent (SE) leading to 65.69 % degradation. Furthermore, the degradation of the drug, in both matrices, follows pseudo-first order kinetics and that at the end of the kinetic monitoring, 96 % and 66 % degradation was obtained for the AS and SE matrices, respectively. Furthermore, SE after treatment showed a reduction of 56.41 %, 39.04 % and 37.14 % for COD, BOD and TOC, respectively. Finally, it was verified that for the aqueous solution before and after treatment there was no toxicity. Thus, it can be stated that the treatment using the proposed electrode has the potential for drug degradation in different matrices.

Authors

Publication Details

Journal
Chemical Engineering and Processing - Process Intensification
Published
2025-02-22
DOI
https://doi.org/10.1016/j.cep.2025.110243
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of magnetite modified graphite electrode: Application in electro-Fenton process for degradation of antidiabetic drug metformin hycloridate

José Luís Ferreira Sá, Vanessa de Oliveira Marques Cavalcanti, Marina Gomes Silva, Daniella Carla Napoleão et al.
Chemical Engineering and Processing - Process Intensification
Electrochemical sensors and biosensors
article

Development of magnetite modified graphite electrode: Application in electro-Fenton process for degradation of antidiabetic drug metformin hycloridate

José Luís Ferreira Sá, Vanessa de Oliveira Marques Cavalcanti, Marina Gomes Silva, Daniella Carla Napoleão, Marta Maria Menezes Bezerra Duarte, Ingrid Larissa da Silva Santana, Alex Leandro Andrade de Lucena, Gabriel Paiva Ourem, Ana Maria Mendonça de Albuquerque Melo
article en

Abstract

• Degradation of metformin by the electro-Fenton process in aqueous and synthetic matrix. • Electrocatalytic improvement of graphite electrode from magnetite impregnation. • Monitoring of electrogenerated oxidizing agents in the electro-Fenton process. • The kinetic evolution of degradation was represented by the pseudo-first order model. • Lower ecotoxicological effect after metformin treatment in aqueous solution. Metformin hydrochloride (CMTF) is a widely used antidiabetic medication. However, the increase in its consumption combined with the fact that only 10 % of the drug is metabolized by the body, can promote contamination of the aquatic environment. Thus, the objective of the work was to develop a modified graphite electrode impregnated with magnetite, not yet reported in the literature, and apply it in the treatment of the drug CMTF via electro-Fenton. The higher degradation percentage obtained for the aqueous solution (AS) was 83.55 %. The developed electrode was applied in the treatment of synthetic effluent (SE) leading to 65.69 % degradation. Furthermore, the degradation of the drug, in both matrices, follows pseudo-first order kinetics and that at the end of the kinetic monitoring, 96 % and 66 % degradation was obtained for the AS and SE matrices, respectively. Furthermore, SE after treatment showed a reduction of 56.41 %, 39.04 % and 37.14 % for COD, BOD and TOC, respectively. Finally, it was verified that for the aqueous solution before and after treatment there was no toxicity. Thus, it can be stated that the treatment using the proposed electrode has the potential for drug degradation in different matrices.

Chemical Engineering and Processing - Process IntensificationVol. 211
Openalex Percentile: Top 98%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.