Annular micro-nano optic fiber sensor based on α-Fe2O3@SiO2@CS imprinting for Cu(II) ion detection

• Combined with simulation analysis, an Annular micro-nano fiber coupler sensing unit was designed and fabricated. • A highly sensitive optic fiber sensor based on FSC-IIP was designed and implemented in this study for the detection of Cu 2+ . • The sensor has the advantages of strong selectivity , manufacturing difficulty, good stability and repeatability, especially selectivity, and the performance is more than 70 times higher than the other metal ions . Sensors for the rapid and easy detection of copper ions (Cu 2+ ) are crucial in drinking water and healthcare. However, this research is still challenging, such as more complicated sample pretreatment and longer detection time. In this paper, a highly sensitive optic fiber sensor for trace detection of Cu 2+ in aqueous solution is proposed. Based on the principle of intermodal interference, the coating method of surface functionalization of functional groups is adopted, and the single-mode fiber (SMF) is bent to form an annular structure to enhance the interference, and the cone pulling machine is used to perform cone pulling treatment before coating a uniform layer of α-Fe 2 O 3 @SiO 2 @CS nanocomposite imprinted material. The amino and hydroxyl groups have specific recognition functions for Cu 2+ and can chelate with Cu 2+ , thus changing the refractive index of the material, which in turn makes the interference spectrum shifted. Furthermore, Cu 2+ is chosen as the template ion to make ion-imprinted materials, and the trace detection of Cu 2+ . The results showed that the interference spectrum was red-shifted with the increase of Cu 2+ concentration in the range of 0–1 μM with a concentration dependence coefficient of 3.35 nm/log·μM, and the maximum detection sensitivity of Cu 2+ reached 1232.52 nm/μM with a good linearity of 0.994. The selectivity of Cu 2+ was more than 70 times that of other ions. In addition, the sensor has the advantages of fast response time, high stability, good reproducibility, simple fabrication and low cost.

Authors

Publication Details

Journal
Optical Fiber Technology
Published
2025-02-21
DOI
https://doi.org/10.1016/j.yofte.2025.104174
Citations
1
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Annular micro-nano optic fiber sensor based on α-Fe2O3@SiO2@CS imprinting for Cu(II) ion detection

Weixiang Yuan, Wenbo Hao, Tao Shen, Yue Feng
1 citations
Optical Fiber Technology
Advanced biosensing and bioanalysis techniques
0.81
article

Annular micro-nano optic fiber sensor based on α-Fe2O3@SiO2@CS imprinting for Cu(II) ion detection

Weixiang Yuan, Wenbo Hao, Tao Shen, Yue Feng
article en
1 citations

Abstract

• Combined with simulation analysis, an Annular micro-nano fiber coupler sensing unit was designed and fabricated. • A highly sensitive optic fiber sensor based on FSC-IIP was designed and implemented in this study for the detection of Cu 2+ . • The sensor has the advantages of strong selectivity , manufacturing difficulty, good stability and repeatability, especially selectivity, and the performance is more than 70 times higher than the other metal ions . Sensors for the rapid and easy detection of copper ions (Cu 2+ ) are crucial in drinking water and healthcare. However, this research is still challenging, such as more complicated sample pretreatment and longer detection time. In this paper, a highly sensitive optic fiber sensor for trace detection of Cu 2+ in aqueous solution is proposed. Based on the principle of intermodal interference, the coating method of surface functionalization of functional groups is adopted, and the single-mode fiber (SMF) is bent to form an annular structure to enhance the interference, and the cone pulling machine is used to perform cone pulling treatment before coating a uniform layer of α-Fe 2 O 3 @SiO 2 @CS nanocomposite imprinted material. The amino and hydroxyl groups have specific recognition functions for Cu 2+ and can chelate with Cu 2+ , thus changing the refractive index of the material, which in turn makes the interference spectrum shifted. Furthermore, Cu 2+ is chosen as the template ion to make ion-imprinted materials, and the trace detection of Cu 2+ . The results showed that the interference spectrum was red-shifted with the increase of Cu 2+ concentration in the range of 0–1 μM with a concentration dependence coefficient of 3.35 nm/log·μM, and the maximum detection sensitivity of Cu 2+ reached 1232.52 nm/μM with a good linearity of 0.994. The selectivity of Cu 2+ was more than 70 times that of other ions. In addition, the sensor has the advantages of fast response time, high stability, good reproducibility, simple fabrication and low cost.

Optical Fiber TechnologyVol. 91
Department of Education, Heilongjiang Province, Harbin Science and Technology Bureau, Science and Technology Department, Heilongjiang Province
Affordable and clean energy
Openalex Percentile: Top 31%
Advanced biosensing and bioanalysis techniques
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.