A preliminary study on the analysis of methane and ethylene by gas chromatography flame ionization detection (GC‐FID) following the sampling by gas permeation through a polymer membrane

Abstract A lab‐fabricated permeation system hyphenated to a gas chromatograph with a flame ionization detector was used to examine the analysis of methane and ethylene. Various concentrations of methane and ethylene in a single or mixture were injected into the permeating chamber containing high‐purity nitrogen or helium atmosphere. The penetrated gases through a poly(ethylene‐ co ‐vinyl acetate) membrane were flushed into a GC–FID equipped with a Porapak packed column for separation and detection using N 2 or He carrier gas. The permeation processes of CH 4 and C 2 H 4 reached a steady state after 10 min. Since this “lag time”, the amounts that penetrated CH 4 and C 2 H 4 were proportional to the permeation time. Within a certain permeation time, the amounts of CH 4 and C 2 H 4 at both sides of the membrane were linearly correlated, facilitating the possibility of quantitative analysis of CH 4 and C 2 H 4 . The permeability coefficients for CH 4 and C 2 H 4 in various permeation conditions were calculated. They showed that the penetration of CH 4 and C 2 H 4 in the He atmosphere was 11 times better compared to the N 2 atmosphere, e.g. the sensitivity of the measurements is also better. This study revealed that permeation through a polymeric membrane could be applied to the analysis of CH 4 and C 2 H 4 or, on a large scale, to the gases or volatile compounds for various applications.

Authors

Institutions

Publication Details

Journal
Vietnam Journal of Chemistry
Published
2025-02-21
DOI
https://doi.org/10.1002/vjch.70001
Citations
1
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A preliminary study on the analysis of methane and ethylene by gas chromatography flame ionization detection (GC‐FID) following the sampling by gas permeation through a polymer membrane

Ngô Xuân Quảng, Van-Dong Nguyen, Nguyen Gia Huy, Nguyen Van Hoang Nhan
1 citations
Vietnam Journal of Chemistry
Advanced Chemical Sensor Technologies
0.67
article

A preliminary study on the analysis of methane and ethylene by gas chromatography flame ionization detection (GC‐FID) following the sampling by gas permeation through a polymer membrane

Ngô Xuân Quảng, Van-Dong Nguyen, Nguyen Gia Huy, Nguyen Van Hoang Nhan
article en
1 citations

Abstract

Abstract A lab‐fabricated permeation system hyphenated to a gas chromatograph with a flame ionization detector was used to examine the analysis of methane and ethylene. Various concentrations of methane and ethylene in a single or mixture were injected into the permeating chamber containing high‐purity nitrogen or helium atmosphere. The penetrated gases through a poly(ethylene‐ co ‐vinyl acetate) membrane were flushed into a GC–FID equipped with a Porapak packed column for separation and detection using N 2 or He carrier gas. The permeation processes of CH 4 and C 2 H 4 reached a steady state after 10 min. Since this “lag time”, the amounts that penetrated CH 4 and C 2 H 4 were proportional to the permeation time. Within a certain permeation time, the amounts of CH 4 and C 2 H 4 at both sides of the membrane were linearly correlated, facilitating the possibility of quantitative analysis of CH 4 and C 2 H 4 . The permeability coefficients for CH 4 and C 2 H 4 in various permeation conditions were calculated. They showed that the penetration of CH 4 and C 2 H 4 in the He atmosphere was 11 times better compared to the N 2 atmosphere, e.g. the sensitivity of the measurements is also better. This study revealed that permeation through a polymeric membrane could be applied to the analysis of CH 4 and C 2 H 4 or, on a large scale, to the gases or volatile compounds for various applications.

Vietnam Journal of ChemistryVol. 64(S1)
Vietnam National University Ho Chi Minh City (VN), Vietnam Academy of Science and Technology (VN)
Clean water and sanitation
Openalex Percentile: Top 35%
Advanced Chemical Sensor Technologies
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.