Novel Approach to Rule-Out Unnecessary Urine Bence Jones Protein Testing: A Serum Free Light Chain Algorithm

<b>Background/Objectives:</b> Bence Jones proteins (BJPs) are monoclonal immunoglobulin free light chains (FLCs) that appear in the urine of patients with plasma cell disorders, including multiple myeloma (MM), Waldenström's macroglobulinemia (WM), or light chain amyloidosis (AL). Their presence can provide valuable information about disease progression and treatment efficacy. These proteins are typically detected through a 24-h urine collection, as recommended by clinical guidelines. However, this method can be inconvenient for both patients and laboratory personnel due to its time-consuming nature and the potential for collection errors. We propose an algorithm based on serum FLC (sFLC) to rule out the presence of BJPs and diminish the need for urine testing. <b>Methods</b>: A retrospective data analysis of 268 serum and urine samples from 44 patients with MM was performed, and cutoffs were established to predict BJP absence: total urine protein (0.115 g/L), sFLC κ/λ ratio (>0.82 λ monoclonality and <1.99 κ monoclonality), and difference of involved-uninvolved FLC (dFLC; <11.93 mg/L). A subsequent algorithm validation was performed in 716 samples from patients who underwent the same testing in routine 2023 other laboratory activity. <b>Results</b>: The validation of these cutoffs to rule out the presence of BJP showed that, if the protocol based on the sFLC κ/λ ratio and dFLC had been applied, 42% of the urine studies would have been avoided, achieving a sensitivity of 93.9% and a false negative rate of 6.11%. <b>Conclusions</b>: We propose a laboratory work protocol that would allow for the avoidance of almost half of the 24-h urine studies based on sFLC measurement, a faster and more objective alternative to urine analysis for screening out the presence of BJP, with a good sensitivity and a low false negative rate.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-02-21
DOI
https://doi.org/10.3390/diagnostics15050525
Citations
2
Primary Topic
Multiple Myeloma Research and Treatments
Type
article
Field-Weighted Citation Impact
3.54
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Approach to Rule-Out Unnecessary Urine Bence Jones Protein Testing: A Serum Free Light Chain Algorithm

Carlos E. Garcia, Nana Beridze Vaktangova, Antonio López González, Sandra García Castañón et al.
2 citations
Diagnostics
Multiple Myeloma Research and Treatments
3.54
article

Novel Approach to Rule-Out Unnecessary Urine Bence Jones Protein Testing: A Serum Free Light Chain Algorithm

Carlos E. Garcia, Nana Beridze Vaktangova, Antonio López González, Sandra García Castañón, Esther González García, C. Alberdi García Del Castillo, F.J. Cepeda Piorno, Eduardo Martínez de Dueñas, Vanessa García Moreira, Paula Chávez Collazos, Jùlia Sanders Vegara
article en
2 citations

Abstract

<b>Background/Objectives:</b> Bence Jones proteins (BJPs) are monoclonal immunoglobulin free light chains (FLCs) that appear in the urine of patients with plasma cell disorders, including multiple myeloma (MM), Waldenström's macroglobulinemia (WM), or light chain amyloidosis (AL). Their presence can provide valuable information about disease progression and treatment efficacy. These proteins are typically detected through a 24-h urine collection, as recommended by clinical guidelines. However, this method can be inconvenient for both patients and laboratory personnel due to its time-consuming nature and the potential for collection errors. We propose an algorithm based on serum FLC (sFLC) to rule out the presence of BJPs and diminish the need for urine testing. <b>Methods</b>: A retrospective data analysis of 268 serum and urine samples from 44 patients with MM was performed, and cutoffs were established to predict BJP absence: total urine protein (0.115 g/L), sFLC κ/λ ratio (>0.82 λ monoclonality and <1.99 κ monoclonality), and difference of involved-uninvolved FLC (dFLC; <11.93 mg/L). A subsequent algorithm validation was performed in 716 samples from patients who underwent the same testing in routine 2023 other laboratory activity. <b>Results</b>: The validation of these cutoffs to rule out the presence of BJP showed that, if the protocol based on the sFLC κ/λ ratio and dFLC had been applied, 42% of the urine studies would have been avoided, achieving a sensitivity of 93.9% and a false negative rate of 6.11%. <b>Conclusions</b>: We propose a laboratory work protocol that would allow for the avoidance of almost half of the 24-h urine studies based on sFLC measurement, a faster and more objective alternative to urine analysis for screening out the presence of BJP, with a good sensitivity and a low false negative rate.

DiagnosticsVol. 15(5)
Universidad de Oviedo (ES), Hospital Universitario San Agustín (ES), Hospital Universitario Miguel Servet (ES), Hospital Universitario De Cabueñes (ES), Instituto de Investigación Sanitaria del Principado de Asturias (ES)
Good health and well-being
Openalex Percentile: Top 9%
Multiple Myeloma Research and Treatments
3.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.