Technical Notes on Liver Elastography: A Guide for Use in Neonates in Intensive Care Units

<b>Background/Objectives:</b> Liver elastography is increasingly used in neonatal intensive care units (NICUs) as a non-invasive, radiation-free, reproducible technique for assessing liver stiffness. This technique demonstrates substantial advantages over conventional ultrasound in diagnosing diffuse liver diseases by providing quantitative measures of tissue elasticity. This article aims to describe the most critical milestones for performing liver elastography ultrasound point-of-care, a tool increasingly used to complement traditional ultrasound in the study of the liver in intensive care units where the population is very susceptible to manipulation. <b>Methods:</b> Techniques such as point-shear wave elastography (pSWE) and two-dimensional shear wave elastography (2D-SWE) have become key in evaluating conditions such as hypoxic-ischemic liver disease, cholestatic diseases, storage and metabolic disorders, or infectious liver conditions. However, despite its usefulness, performing elastography in neonates, particularly in those weighing less than 1000 g or in high-frequency oscillatory ventilation, presents notable challenges, including the extreme sensitivity of neonates to touch, noise, and temperature changes and the difficulty in obtaining accurate measurements due to limited hepatic depth. <b>Results:</b> Key factors for the success of sonoelastography in this population include minimizing contact time, adjusting mechanical and thermal indices to meet biosecurity guidelines, and ensuring patient comfort and stability during the procedure. Despite these challenges, elastography has proven helpful in routine clinical practice. <b>Conclusions:</b> The growing evidence on elastography has provided standardized reference values, further enhancing its clinical applicability in NICU settings.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-02-21
DOI
https://doi.org/10.3390/jcm14051435
Citations
1
Primary Topic
Liver Disease Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Technical Notes on Liver Elastography: A Guide for Use in Neonates in Intensive Care Units

Alejandra Aguado del Hoyo, Miguel Á. Ortega, Juan A. De León-Luis, Ángel Lancharro et al.
1 citations
Journal of Clinical Medicine
Liver Disease Diagnosis and Treatment
1.35
article

Technical Notes on Liver Elastography: A Guide for Use in Neonates in Intensive Care Units

Alejandra Aguado del Hoyo, Miguel Á. Ortega, Juan A. De León-Luis, Ángel Lancharro, María del Carmen Sánchez Gómez de Orgaz
article en
1 citations

Abstract

<b>Background/Objectives:</b> Liver elastography is increasingly used in neonatal intensive care units (NICUs) as a non-invasive, radiation-free, reproducible technique for assessing liver stiffness. This technique demonstrates substantial advantages over conventional ultrasound in diagnosing diffuse liver diseases by providing quantitative measures of tissue elasticity. This article aims to describe the most critical milestones for performing liver elastography ultrasound point-of-care, a tool increasingly used to complement traditional ultrasound in the study of the liver in intensive care units where the population is very susceptible to manipulation. <b>Methods:</b> Techniques such as point-shear wave elastography (pSWE) and two-dimensional shear wave elastography (2D-SWE) have become key in evaluating conditions such as hypoxic-ischemic liver disease, cholestatic diseases, storage and metabolic disorders, or infectious liver conditions. However, despite its usefulness, performing elastography in neonates, particularly in those weighing less than 1000 g or in high-frequency oscillatory ventilation, presents notable challenges, including the extreme sensitivity of neonates to touch, noise, and temperature changes and the difficulty in obtaining accurate measurements due to limited hepatic depth. <b>Results:</b> Key factors for the success of sonoelastography in this population include minimizing contact time, adjusting mechanical and thermal indices to meet biosecurity guidelines, and ensuring patient comfort and stability during the procedure. Despite these challenges, elastography has proven helpful in routine clinical practice. <b>Conclusions:</b> The growing evidence on elastography has provided standardized reference values, further enhancing its clinical applicability in NICU settings.

Journal of Clinical MedicineVol. 14(5)
Universidad Complutense de Madrid (ES), Universidad de Alcalá (ES), Instituto Cajal (ES), Hospital General Universitario Gregorio Marañón (ES), Instituto Ramón y Cajal de Investigación Sanitaria (ES)
Instituto de Salud Carlos III
Good health and well-being
Openalex Percentile: Top 23%
Liver Disease Diagnosis and Treatment
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.