Carbon fiber–reinforced PEEK implants in oncologic spine surgery: a multicenter experience on implications for postoperative patient management

Low overall complication and low surgical revision rates were reported. Because of the possibility of higher quality MRI follow-up due to CFRP implants, complications or relevant tumor recurrence during follow-up were detected safely and at a high rate in cases where MRI was performed. However, consequent MRI follow-up was not homogeneously performed, and adjuvant radiotherapy was handled rather heterogeneously. These findings lead to the conclusion that until homogeneous adjuvant follow-up and treatment standards are established, the potential benefits available through the use of CFRP implants are not exhausted, and the decision for the use of CFRP implants in comparison to standard titanium implants remains case-to-case based.

Authors

Institutions

Publication Details

Journal
Journal of Neurosurgery Spine
Published
2025-02-21
DOI
https://doi.org/10.3171/2024.10.spine24753
Citations
7
Primary Topic
Management of metastatic bone disease
Type
article
Field-Weighted Citation Impact
14.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Carbon fiber–reinforced PEEK implants in oncologic spine surgery: a multicenter experience on implications for postoperative patient management

Peter Vajkoczy, Carolin Albrecht, Bernhard Meyer, Vanessa Hubertus et al.
7 citations
Journal of Neurosurgery Spine
Management of metastatic bone disease
14.04
article

Carbon fiber–reinforced PEEK implants in oncologic spine surgery: a multicenter experience on implications for postoperative patient management

Peter Vajkoczy, Carolin Albrecht, Bernhard Meyer, Vanessa Hubertus, Sara Lener, Stephanie Elisabeth Combs, Mehmet Turgut, Arthur Wagner, R Gmeiner, Dragan Janković, Julia Onken, Nils Hecht, Darius Kalasauskas, Claudius Thomé, Florian Ringel, Güliz Acker, Melanie Brüßeler, H. Miller
article en
7 citations

Abstract

Low overall complication and low surgical revision rates were reported. Because of the possibility of higher quality MRI follow-up due to CFRP implants, complications or relevant tumor recurrence during follow-up were detected safely and at a high rate in cases where MRI was performed. However, consequent MRI follow-up was not homogeneously performed, and adjuvant radiotherapy was handled rather heterogeneously. These findings lead to the conclusion that until homogeneous adjuvant follow-up and treatment standards are established, the potential benefits available through the use of CFRP implants are not exhausted, and the decision for the use of CFRP implants in comparison to standard titanium implants remains case-to-case based.

Journal of Neurosurgery SpineVol. 42(5)
Innsbruck Medical University (AT), German Cancer Research Center (DE), Universität Innsbruck (AT), Johannes Gutenberg University Mainz (DE), TUM Klinikum (DE), Humboldt-Universität zu Berlin (DE), Berlin Institute of Health at Charité - Universitätsmedizin Berlin (DE), Technical University of Munich (DE), Freie Universität Berlin (DE), Charité - Universitätsmedizin Berlin (DE)
Good health and well-being
Openalex Percentile: Top 1%
Management of metastatic bone disease
14.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.