Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health

This study aims to validate the accuracy of low-cost fitness smartwatches by comparing their data with gold-standard measurements for cardiovascular and physical activity parameters. The study enrolled 50 subjects, 26 undergoing validation testing for heart rate, blood oxygen saturation (SpO2), and sleep data against polysomnography (PSG). Additionally, 24 subjects participated in the 3-Minute Walk Test (3MWT) and Stairs Climbing (SC), with step counts validated against manual video calculations. Results showed no significant difference between the device's measurements and gold standard values for shallow sleep, deep sleep, REM time, mean heart rate, minimum heart rate, and SpO2. However, the device significantly underestimated manually counted steps (p = 0.009 (3MWT); p = 0.012 (SC)), total sleep duration (p = 0.004), and wake time (p = 8.94 × 10<sup>-8</sup>) while overestimating maximum heart rate (p = 0.011). These findings highlight the importance of accurate validation and interpretation of wearable device data in clinical contexts. Given these limitations, excluding the device's readings in future analyses is recommended to maintain data reliability and research integrity. This study underscores the need for ongoing validation and improvement of wearable technology to ensure its reliability and effectiveness in healthcare.

Authors

Institutions

Publication Details

Journal
Journal of Visualized Experiments
Published
2025-02-21
DOI
https://doi.org/10.3791/67674
Primary Topic
Mobile Health and mHealth Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health

Wen‐Song Tan, M. Koh, Afrina Adlyna Mohamad Matrol, Hang Cheng Ong et al.
Journal of Visualized Experiments
Mobile Health and mHealth Applications
article

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health

Wen‐Song Tan, M. Koh, Afrina Adlyna Mohamad Matrol, Hang Cheng Ong, Letchumy Praba Ramanaidu, Shier Nee Saw
article en

Abstract

This study aims to validate the accuracy of low-cost fitness smartwatches by comparing their data with gold-standard measurements for cardiovascular and physical activity parameters. The study enrolled 50 subjects, 26 undergoing validation testing for heart rate, blood oxygen saturation (SpO2), and sleep data against polysomnography (PSG). Additionally, 24 subjects participated in the 3-Minute Walk Test (3MWT) and Stairs Climbing (SC), with step counts validated against manual video calculations. Results showed no significant difference between the device's measurements and gold standard values for shallow sleep, deep sleep, REM time, mean heart rate, minimum heart rate, and SpO2. However, the device significantly underestimated manually counted steps (p = 0.009 (3MWT); p = 0.012 (SC)), total sleep duration (p = 0.004), and wake time (p = 8.94 × 10<sup>-8</sup>) while overestimating maximum heart rate (p = 0.011). These findings highlight the importance of accurate validation and interpretation of wearable device data in clinical contexts. Given these limitations, excluding the device's readings in future analyses is recommended to maintain data reliability and research integrity. This study underscores the need for ongoing validation and improvement of wearable technology to ensure its reliability and effectiveness in healthcare.

Journal of Visualized Experiments(216)
Agency for Science, Technology and Research (SG), Information Technology University (PK), University of Malaya (MY)
Openalex Percentile: Top 95%
Mobile Health and mHealth Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.