Measuring complex for determining the efficiency of fire extinguishing equipment with fine spray water

The work presents and substantiates the design and operation mode of the measuring complex for determining the effectiveness of technical means of fire extinguishing with finely sprayed water. The measuring complex consists of 5 integrated humidity and temperature sensors, an information processing unit with a memory card and a power supply unit. The sensors are connected to the information processing unit (display driver board and sd card slot), which allows you to process and record the received information on a memory card. The measuring complex is powered by a laptop or power bank connected to the information processing unit. Processing of measurement results is carried out using computing equipment (laptop, tablet, etc.) with the pre-installed WPS Office or Microsoft Office program. Information is read from the sensors every second, and the total measurement time is limited by the memory card. The error of humidity and temperature measurements by the developed complex is determined based on the measurement error of the sensors used. For measurements, a scheme is proposed where the sensors are placed at different heights and distances from the center of the internal fire. Due to the use of the measuring complex, temperature and humidity indicators are measured when determining the effectiveness of modern technical means of fire extinguishing with fine spray, which ensure minimal consumption of extinguishing agent, mobility and have a simple design. By evaluating the efficiency of technical means of fire extinguishing with finely sprayed water, their scope of use is determined, and due to their mobility and autonomy, the level of safety of the personnel of fire and rescue units during fire extinguishing, including in the conditions of combat operations, will be increased.

Authors

Institutions

Publication Details

Journal
Problems of Emergency Situations
Published
2024-12-01
DOI
https://doi.org/10.52363/2524-0226-2024-40-12
Primary Topic
Environmental and Industrial Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measuring complex for determining the efficiency of fire extinguishing equipment with fine spray water

Dmytro Dubinin
Problems of Emergency Situations
Environmental and Industrial Safety
article

Measuring complex for determining the efficiency of fire extinguishing equipment with fine spray water

Dmytro Dubinin
article en

Abstract

The work presents and substantiates the design and operation mode of the measuring complex for determining the effectiveness of technical means of fire extinguishing with finely sprayed water. The measuring complex consists of 5 integrated humidity and temperature sensors, an information processing unit with a memory card and a power supply unit. The sensors are connected to the information processing unit (display driver board and sd card slot), which allows you to process and record the received information on a memory card. The measuring complex is powered by a laptop or power bank connected to the information processing unit. Processing of measurement results is carried out using computing equipment (laptop, tablet, etc.) with the pre-installed WPS Office or Microsoft Office program. Information is read from the sensors every second, and the total measurement time is limited by the memory card. The error of humidity and temperature measurements by the developed complex is determined based on the measurement error of the sensors used. For measurements, a scheme is proposed where the sensors are placed at different heights and distances from the center of the internal fire. Due to the use of the measuring complex, temperature and humidity indicators are measured when determining the effectiveness of modern technical means of fire extinguishing with fine spray, which ensure minimal consumption of extinguishing agent, mobility and have a simple design. By evaluating the efficiency of technical means of fire extinguishing with finely sprayed water, their scope of use is determined, and due to their mobility and autonomy, the level of safety of the personnel of fire and rescue units during fire extinguishing, including in the conditions of combat operations, will be increased.

Problems of Emergency Situations
National University of Civil Protection of Ukraine (UA)
Openalex Percentile: Top 77%
Environmental and Industrial Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Measuring complex for determining the efficiency of fire extinguishing equipment with fine spray water — Dmytro Dubinin · Problems of Emergency Situations (2024) | TGRS Research Map | TGRS