Short-acting β<sub>2</sub> Agonist Inhalation Therapy for Asthma or Chronic Obstructive Pulmonary Disease with a High-flow Nasal Cannula in Japan - An Online Questionnaire Survey by the Japanese Respiratory Society, Japanese Society of In

Objective Short-acting β<sub>2</sub> agonists (SABAs) are key drugs for the treatment of asthma and chronic obstructive pulmonary disease (COPD). A high-flow nasal cannula (HFNC) is widely used for respiratory failure. Recently, a consensus statement on inhalation therapy with HFNC has been published. However, information regarding the real-world state of inhalation therapy practices in Japan is lacking. Methods An anonymous online questionnaire survey endorsed by three Japanese associations (the Japanese Respiratory Society, Japanese Society of Intensive Care Medicine, and Japanese Society of Respiratory Care Medicine) was administered from October to November 2023. Responses were stratified into three questions: Question A, "Do you routinely treat patients with asthma and COPD?" Question B "Do you routinely perform high-flow therapy?"; and Question C "How do you provide inhaled SABAs during high-flow therapy in patients with asthma or COPD?" Patients This questionnaire was distributed to all members of the three societies. Results Of the 567 participants who completed the questionnaire, 387 responded to all 3 questions. When a nebulizer was included in high-flow devices, the frequencies of using an ultrasonic nebulizer, jet, vibrating mesh, other, or not performing nebulization were 49.1%, 30.8%, 5.4%, 0.5%, and 14.2%, respectively; when a nebulizer was included in high-flow devices, these frequencies were 24.0%, 11.1%, 16.0%, 0%, and 48.9%, respectively. Conclusion Various techniques for inhalation therapy are being employed, revealing a discrepancy between current practices in Japan and the recommendations outlined in the consensus statement.

Authors

Institutions

Publication Details

Journal
Internal Medicine
Published
2025-02-21
DOI
https://doi.org/10.2169/internalmedicine.4863-24
Citations
1
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
1.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Short-acting β2 Agonist Inhalation Therapy for Asthma or Chronic Obstructive Pulmonary Disease with a High-flow Nasal Cannula in Japan - An Online Questionnaire Survey by the Japanese Respiratory Society, Japanese Society of In

Toru Oga, Miyuki Okuda, Ken‐ichi Ito, Hiroshi Kobe et al.
1 citations
Internal Medicine
Respiratory Support and Mechanisms
1.52
article

Short-acting β2 Agonist Inhalation Therapy for Asthma or Chronic Obstructive Pulmonary Disease with a High-flow Nasal Cannula in Japan - An Online Questionnaire Survey by the Japanese Respiratory Society, Japanese Society of In

Toru Oga, Miyuki Okuda, Ken‐ichi Ito, Hiroshi Kobe, Takeshi Yoshida
article en
1 citations

Abstract

Objective Short-acting β<sub>2</sub> agonists (SABAs) are key drugs for the treatment of asthma and chronic obstructive pulmonary disease (COPD). A high-flow nasal cannula (HFNC) is widely used for respiratory failure. Recently, a consensus statement on inhalation therapy with HFNC has been published. However, information regarding the real-world state of inhalation therapy practices in Japan is lacking. Methods An anonymous online questionnaire survey endorsed by three Japanese associations (the Japanese Respiratory Society, Japanese Society of Intensive Care Medicine, and Japanese Society of Respiratory Care Medicine) was administered from October to November 2023. Responses were stratified into three questions: Question A, "Do you routinely treat patients with asthma and COPD?" Question B "Do you routinely perform high-flow therapy?"; and Question C "How do you provide inhaled SABAs during high-flow therapy in patients with asthma or COPD?" Patients This questionnaire was distributed to all members of the three societies. Results Of the 567 participants who completed the questionnaire, 387 responded to all 3 questions. When a nebulizer was included in high-flow devices, the frequencies of using an ultrasonic nebulizer, jet, vibrating mesh, other, or not performing nebulization were 49.1%, 30.8%, 5.4%, 0.5%, and 14.2%, respectively; when a nebulizer was included in high-flow devices, these frequencies were 24.0%, 11.1%, 16.0%, 0%, and 48.9%, respectively. Conclusion Various techniques for inhalation therapy are being employed, revealing a discrepancy between current practices in Japan and the recommendations outlined in the consensus statement.

Internal MedicineVol. 64(17)
Naragakuen University (JP), Kawasaki Medical School (JP), Osaka Minami Medical Center (JP), The University of Osaka (JP)
Japanese Respiratory Society
Good health and well-being
Openalex Percentile: Top 22%
Respiratory Support and Mechanisms
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.