Lithium isotopic analysis in depleted lithium salts

Lithium isotope separation processes require characterization of the isotopic compositions of the different output phases of the process. While considerable effort to develop isotope separation methods has been ongoing for decades, the analytical methods associated with these analyses are rarely provided. In this work three types of mass spectrometers (Q-ICP-MS, MC-ICP-MS, TIMS) were tested for the ability to measure depleted lithium salts that are relevant materials for isotopic separations. Results indicate that, once stabilized, the Q-ICP-MS can provide equal precision for Li isotopic samples compared to TIMS or MC-ICP-MS. However, MC-ICP-MS consistently provides the highest precision for salts with natural isotopic abundances , whereas Q-ICP-MS provides equal or better precision in the depleted salts. These data demonstrate that Q-ICP-MS is an appropriate choice for analysis of depleted lithium salts, especially when rapid analyses are desired for near-online process monitoring.

Authors

Institutions

Publication Details

Journal
Progress in Nuclear Energy
Published
2025-02-21
DOI
https://doi.org/10.1016/j.pnucene.2025.105674
Citations
1
Primary Topic
Chemical Synthesis and Characterization
Type
article
Field-Weighted Citation Impact
1.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lithium isotopic analysis in depleted lithium salts

Alan Kruizenga, Sean Scott, Kali M. Melby, Sara Mastromarino et al.
1 citations
Progress in Nuclear Energy
Chemical Synthesis and Characterization
1.00
article

Lithium isotopic analysis in depleted lithium salts

Alan Kruizenga, Sean Scott, Kali M. Melby, Sara Mastromarino, Kirby Hobbs, I. S. Anderson, Jeff Williams, Norbert Gajos, C. L. Berry
article en
1 citations

Abstract

Lithium isotope separation processes require characterization of the isotopic compositions of the different output phases of the process. While considerable effort to develop isotope separation methods has been ongoing for decades, the analytical methods associated with these analyses are rarely provided. In this work three types of mass spectrometers (Q-ICP-MS, MC-ICP-MS, TIMS) were tested for the ability to measure depleted lithium salts that are relevant materials for isotopic separations. Results indicate that, once stabilized, the Q-ICP-MS can provide equal precision for Li isotopic samples compared to TIMS or MC-ICP-MS. However, MC-ICP-MS consistently provides the highest precision for salts with natural isotopic abundances , whereas Q-ICP-MS provides equal or better precision in the depleted salts. These data demonstrate that Q-ICP-MS is an appropriate choice for analysis of depleted lithium salts, especially when rapid analyses are desired for near-online process monitoring.

Progress in Nuclear EnergyVol. 183
Battelle (US), Pacific Northwest National Laboratory (US), Kairos (United States) (US), Power Standards Lab (United States) (US), Kairos Power (United States)
U.S. Department of Energy, Battelle, Office of Nuclear Energy, Idaho National Laboratory
Openalex Percentile: Top 26%
Chemical Synthesis and Characterization
1.00
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.