Establishing the feasibility and reliability of broadband absorption spectroscopy for measuring cerebral water content in adults

Broadband absorption spectroscopy (BAS) has the potential to fill an unmet need for a non-invasive monitor of cerebral edema. In this work, we demonstrated the feasibility of BAS to measure water content in the adult human head by quantifying measurement reliability and the influence of ambient light on BAS-measured parameters. We observed strong inter-operator reliability of BAS-measurement of water (R<sup>2</sup> = 0.69, Lin's CCC = 0.78, p < 0.01). Similar significant reliability was observed for lipid (R<sup>2</sup> = 0.54), oxygen saturation (R<sup>2</sup> = 0.81), and total hemoglobin (R<sup>2</sup> = 0.44). Ambient light increased water content by approximately 2-3% compared to dark conditions.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2025-02-20
DOI
https://doi.org/10.1364/boe.551192
Citations
1
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Establishing the feasibility and reliability of broadband absorption spectroscopy for measuring cerebral water content in adults

Rodrigo M. Forti, Ofer Sadan, Owen Samuels, Prem Kandiah et al.
1 citations
Biomedical Optics Express
Optical Imaging and Spectroscopy Techniques
1.36
article

Establishing the feasibility and reliability of broadband absorption spectroscopy for measuring cerebral water content in adults

Rodrigo M. Forti, Ofer Sadan, Owen Samuels, Prem Kandiah, Shasha Bai, Vidisha Goyal, Feras Akbik, Erin M. Buckley, Michael D. Arrington, L. H. Harris
article en
1 citations

Abstract

Broadband absorption spectroscopy (BAS) has the potential to fill an unmet need for a non-invasive monitor of cerebral edema. In this work, we demonstrated the feasibility of BAS to measure water content in the adult human head by quantifying measurement reliability and the influence of ambient light on BAS-measured parameters. We observed strong inter-operator reliability of BAS-measurement of water (R<sup>2</sup> = 0.69, Lin's CCC = 0.78, p < 0.01). Similar significant reliability was observed for lipid (R<sup>2</sup> = 0.54), oxygen saturation (R<sup>2</sup> = 0.81), and total hemoglobin (R<sup>2</sup> = 0.44). Ambient light increased water content by approximately 2-3% compared to dark conditions.

Biomedical Optics ExpressVol. 16(3)
Georgia Institute of Technology (US), Children's Hospital of Philadelphia (US), Emory University (US), Emory University Hospital (US), The Wallace H. Coulter Department of Biomedical Engineering (US), Children's Healthcare of Atlanta (US)
National Institute of Neurological Disorders and Stroke
Clean water and sanitation
Openalex Percentile: Top 23%
Optical Imaging and Spectroscopy Techniques
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Establishing the feasibility and reliability of broadband absorption spectroscopy for measuring cerebral water content in adults — Rodrigo M. Forti, Ofer Sadan, et al. · Biomedical Optics Express (2025) | TGRS Research Map | TGRS