Investigating the impact of different time delays between OCT signal and k-clock signal on the structural and vascular imaging in SS-OCT

High-quality swept-source optical coherence tomography (SS-OCT) imaging systems require precise synchronization between the OCT signal and the k-clock signal. However, in practical applications, an uncertain time delay between these signals can cause inaccurate k-space sampling, leading to degraded imaging resolution. This study first simulates the axial resolution degradation curve caused by varying time delays and experimentally validates the results. Additionally, the effects of different time delays on both OCT structural and blood flow images are systematically investigated through experiments. To address this issue, a numerical calibration method is implemented to compensate for the nonlinear phase component. This approach involves acquiring two reflection signals at different depths, unwrapping the phase, performing high-order polynomial fitting, and removing nonlinear phase components induced by time delay, which effectively corrects the resolution degradation. Experiments conducted on semi-transparent white tape, blood flow phantom, and human nailfold demonstrate that the proposed correction algorithm significantly improves the axial resolution of both structural and blood flow images. The findings indicate that our investigation and the developed calibration method are instrumental in reconstructing high-resolution SS-OCT images, which are essential for accurate diagnosis and effective treatment monitoring in clinical applications.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2025-02-20
DOI
https://doi.org/10.1364/boe.553982
Citations
2
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigating the impact of different time delays between OCT signal and k-clock signal on the structural and vascular imaging in SS-OCT

Yanping Huang, Miaohua Chen, Gongpu Lan, Haixia Qiu et al.
2 citations
Biomedical Optics Express
Optical Coherence Tomography Applications
1.35
article

Investigating the impact of different time delays between OCT signal and k-clock signal on the structural and vascular imaging in SS-OCT

Yanping Huang, Miaohua Chen, Gongpu Lan, Haixia Qiu, Jia Qin, Peijun Tang, Jingjiang Xu, Z. H. Lu, Lin An
article en
2 citations

Abstract

High-quality swept-source optical coherence tomography (SS-OCT) imaging systems require precise synchronization between the OCT signal and the k-clock signal. However, in practical applications, an uncertain time delay between these signals can cause inaccurate k-space sampling, leading to degraded imaging resolution. This study first simulates the axial resolution degradation curve caused by varying time delays and experimentally validates the results. Additionally, the effects of different time delays on both OCT structural and blood flow images are systematically investigated through experiments. To address this issue, a numerical calibration method is implemented to compensate for the nonlinear phase component. This approach involves acquiring two reflection signals at different depths, unwrapping the phase, performing high-order polynomial fitting, and removing nonlinear phase components induced by time delay, which effectively corrects the resolution degradation. Experiments conducted on semi-transparent white tape, blood flow phantom, and human nailfold demonstrate that the proposed correction algorithm significantly improves the axial resolution of both structural and blood flow images. The findings indicate that our investigation and the developed calibration method are instrumental in reconstructing high-resolution SS-OCT images, which are essential for accurate diagnosis and effective treatment monitoring in clinical applications.

Biomedical Optics ExpressVol. 16(3)
Foshan University (CN), South China Normal University (CN), Chinese PLA General Hospital (CN), Pearl River Hydraulic Research Institute (CN), Hangzhou Dianzi University (CN)
National Natural Science Foundation of China, Basic and Applied Basic Research Foundation of Guangdong Province
Openalex Percentile: Top 22%
Optical Coherence Tomography Applications
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.