Luminescent immunochromatography based on Eu3+ coordination compounds for detection of pathogenic microorganisms and bacterial toxins

Introduction . Increasing the sensitivity of immunochromatographic assay as an express method for detection and diagnosis of pathogenic microorganisms and toxins is a relevant task with regard to ensuring food safety and population health in general. Objective. Development of a prototype of a video digital recorder of luminescent immunochromatograms (RLI-Eu 3+ ) and luminescent immunochromatographic tests (LICHT) adapted to a device based on microspheres with europium compounds. Comparison of the sensitivity of LICHT and AuNPs-based immunochromatography assay (ICA) tests to increase the sensitivity of the method for detection of pathogenic microorganisms and their toxins. Material and methods . Submicron polymer microspheres labeled with organic complexes of trivalent europium (Eu 3+ ) were used as a luminescent label for immunochromatography. LICHT were recorded using the developed RLI-Eu 3+ recorder. Results. The detection threshold of the Eu 3+ luminescent complex on the immunochromatographic membrane was shown to be 2 pg/mm 2 , with the linearity of the readings ranging within 2–200 pg/mm 2 . The coefficients of variation of the instrument readings in the luminescent complex concentration range of 20–200 pg/mm 2 and 2–20 pg/mm 2 were found to be less than 5% and 10%, respectively. Using LICHT and the RLI-Eu 3+ device, detection thresholds were determined as follows: cholera toxin — 10 ng/mL, staphylococcal enterotoxin type B — 0.5 ng/mL, plague pathogen cells — 1×10 3 cells/mL, anthrax pathogen spores — 5×10 3 spores/mL, Crimean-Congo hemorrhagic fever (CCHF) virus antigens — at a dilution of 1:640,000. Conclusions. The developed video digital recorder RLI-Eu 3+ and LICHT based on europium coordination compounds enabled the detection threshold of pathogenic microorganisms and bacterial toxins to be reduced by 20–128 times compared to immunochromatographic tests based on colloidal gold (CG) for the same pathogens.

Authors

Publication Details

Journal
Extreme Medicine
Published
2025-02-20
DOI
https://doi.org/10.47183/mes.2025-257
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Luminescent immunochromatography based on Eu3+ coordination compounds for detection of pathogenic microorganisms and bacterial toxins

KK Styazhkin, S. P. Yarkov, E. K. Shaulina, И. В. Шиленко et al.
Extreme Medicine
Biosensors and Analytical Detection
article

Luminescent immunochromatography based on Eu3+ coordination compounds for detection of pathogenic microorganisms and bacterial toxins

KK Styazhkin, S. P. Yarkov, E. K. Shaulina, И. В. Шиленко, SI Tretyakov, A. Mandaji, D. A. Zenkov, Yu. N. Ishkov
article en

Abstract

Introduction . Increasing the sensitivity of immunochromatographic assay as an express method for detection and diagnosis of pathogenic microorganisms and toxins is a relevant task with regard to ensuring food safety and population health in general. Objective. Development of a prototype of a video digital recorder of luminescent immunochromatograms (RLI-Eu 3+ ) and luminescent immunochromatographic tests (LICHT) adapted to a device based on microspheres with europium compounds. Comparison of the sensitivity of LICHT and AuNPs-based immunochromatography assay (ICA) tests to increase the sensitivity of the method for detection of pathogenic microorganisms and their toxins. Material and methods . Submicron polymer microspheres labeled with organic complexes of trivalent europium (Eu 3+ ) were used as a luminescent label for immunochromatography. LICHT were recorded using the developed RLI-Eu 3+ recorder. Results. The detection threshold of the Eu 3+ luminescent complex on the immunochromatographic membrane was shown to be 2 pg/mm 2 , with the linearity of the readings ranging within 2–200 pg/mm 2 . The coefficients of variation of the instrument readings in the luminescent complex concentration range of 20–200 pg/mm 2 and 2–20 pg/mm 2 were found to be less than 5% and 10%, respectively. Using LICHT and the RLI-Eu 3+ device, detection thresholds were determined as follows: cholera toxin — 10 ng/mL, staphylococcal enterotoxin type B — 0.5 ng/mL, plague pathogen cells — 1×10 3 cells/mL, anthrax pathogen spores — 5×10 3 spores/mL, Crimean-Congo hemorrhagic fever (CCHF) virus antigens — at a dilution of 1:640,000. Conclusions. The developed video digital recorder RLI-Eu 3+ and LICHT based on europium coordination compounds enabled the detection threshold of pathogenic microorganisms and bacterial toxins to be reduced by 20–128 times compared to immunochromatographic tests based on colloidal gold (CG) for the same pathogens.

Extreme MedicineVol. 27(1)
Openalex Percentile: Top 97%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.