Measurements of Diffusion Coefficients in Liquid Alloys Using Two Measurement Points of <i>In Situ</i> X-Ray Fluorescence Analysis

The objective of this study is to quantify the improvement of diffusion experiments in liquid alloys by using two measurement points of in situ X-ray fluorescence analysis ( in situ XRF). The impurity diffusion coefficient of Bi in liquid Sn at 573 K was measured by monitoring the temporal change in the Bi concentration at two fixed points using in situ XRF. In the present study, two XRF measurement points were set in order to determine two unknown parameters that corresponded to the diffusion coefficient and the initial concentration at the measurement point just after complete melting. When only one measurement point is set for in situ XRF, the initial concentration is treated as a variable and the obtained impurity diffusion coefficients of Bi deviated by 20-30% from the reliable reference data. By using two measurement points for in situ XRF, the obtained impurity diffusion coefficient of Bi was (2.44±0.08)×10 -9 m 2 s -1 and agreed with the reference data in the reported uncertainty of ±10%.

Authors

Institutions

Publication Details

Journal
Defect and diffusion forum/Diffusion and defect data, solid state data. Part A, Defect and diffusion forum
Published
2025-02-20
DOI
https://doi.org/10.4028/p-mi3qpt
Citations
1
Primary Topic
Thermodynamic and Structural Properties of Metals and Alloys
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurements of Diffusion Coefficients in Liquid Alloys Using Two Measurement Points of In Situ X-Ray Fluorescence Analysis

Yoshihiro Kobayashi, Masato Shiinoki, Tadahiko Masaki, Shinsuke Suzuki
1 citations
Defect and diffusion forum/Diffusion and defect data, solid state data. Part A, Defect and diffusion forum
Thermodynamic and Structural Properties of Metals and Alloys
0.71
article

Measurements of Diffusion Coefficients in Liquid Alloys Using Two Measurement Points of In Situ X-Ray Fluorescence Analysis

Yoshihiro Kobayashi, Masato Shiinoki, Tadahiko Masaki, Shinsuke Suzuki
article en
1 citations

Abstract

The objective of this study is to quantify the improvement of diffusion experiments in liquid alloys by using two measurement points of in situ X-ray fluorescence analysis ( in situ XRF). The impurity diffusion coefficient of Bi in liquid Sn at 573 K was measured by monitoring the temporal change in the Bi concentration at two fixed points using in situ XRF. In the present study, two XRF measurement points were set in order to determine two unknown parameters that corresponded to the diffusion coefficient and the initial concentration at the measurement point just after complete melting. When only one measurement point is set for in situ XRF, the initial concentration is treated as a variable and the obtained impurity diffusion coefficients of Bi deviated by 20-30% from the reliable reference data. By using two measurement points for in situ XRF, the obtained impurity diffusion coefficient of Bi was (2.44±0.08)×10 -9 m 2 s -1 and agreed with the reference data in the reported uncertainty of ±10%.

Defect and diffusion forum/Diffusion and defect data, solid state data. Part A, Defect and diffusion forumVol. 439
Waseda University (JP), Shibaura Institute of Technology (JP)
Openalex Percentile: Top 36%
Thermodynamic and Structural Properties of Metals and Alloys
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.