Comparison of keratometric data by optical biometers and Scheimpflug camera in patients before lens surgery

Purpose. To compare keratometry values determined by three different devices in patients before lens surgery. Material and methods. 55 patients which mean values of keratometry were compared using two optical biometers (IOL-Master 500, Carl Zeiss Meditec AG, Germany, and Tomey OA-2000, Japan) and Scheimpflug camera (Pentacam-HR, Oculus, Germany), according to which the values of standard keratometry (Axial), equivalent keratometric indicators (EKR) and total corneal refractive power (TCRP) were used. Results. Mean keratometry values according to IOL-Master 500 were 43.47±1.36, Tomey OA-2000 — 43.46±1.24, Axial — 43.34±1.4, EKR — 43.19±1.4, TCRP — 42.7±1.4. Pentacam-HR keratometric data (for all maps and zones) are significantly lower than the corneal optical power determined by IOL-Master 500. Comparison of Tomey OA-2000 and Pentacam-HR revealed statistically significant low values of keratometry according to TCRP and EKR maps. Conclusion. The standard keratometry results used in most IOL calculation formulas may vary depending on the method of their determination. The values of the optical corneal power according to keratometry data, taking into account the posterior surface of the cornea, are significantly lower than the values of standard keratometry, which is due to the leveling of the index 1.3375. Key words: keratometry, corneal power, biometrics, keratotopography

Authors

Publication Details

Journal
Fyodorov journal of ophthalmic surgery
Published
2024-12-04
DOI
https://doi.org/10.25276/0235-4160-2024-4-34-40
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of keratometric data by optical biometers and Scheimpflug camera in patients before lens surgery

S.V. Shukhaev, Y.M. Petrosyan, I.B. Litvin, Ernest V. Boiko
Fyodorov journal of ophthalmic surgery
Corneal surgery and disorders
article

Comparison of keratometric data by optical biometers and Scheimpflug camera in patients before lens surgery

S.V. Shukhaev, Y.M. Petrosyan, I.B. Litvin, Ernest V. Boiko
article en

Abstract

Purpose. To compare keratometry values determined by three different devices in patients before lens surgery. Material and methods. 55 patients which mean values of keratometry were compared using two optical biometers (IOL-Master 500, Carl Zeiss Meditec AG, Germany, and Tomey OA-2000, Japan) and Scheimpflug camera (Pentacam-HR, Oculus, Germany), according to which the values of standard keratometry (Axial), equivalent keratometric indicators (EKR) and total corneal refractive power (TCRP) were used. Results. Mean keratometry values according to IOL-Master 500 were 43.47±1.36, Tomey OA-2000 — 43.46±1.24, Axial — 43.34±1.4, EKR — 43.19±1.4, TCRP — 42.7±1.4. Pentacam-HR keratometric data (for all maps and zones) are significantly lower than the corneal optical power determined by IOL-Master 500. Comparison of Tomey OA-2000 and Pentacam-HR revealed statistically significant low values of keratometry according to TCRP and EKR maps. Conclusion. The standard keratometry results used in most IOL calculation formulas may vary depending on the method of their determination. The values of the optical corneal power according to keratometry data, taking into account the posterior surface of the cornea, are significantly lower than the values of standard keratometry, which is due to the leveling of the index 1.3375. Key words: keratometry, corneal power, biometrics, keratotopography

Fyodorov journal of ophthalmic surgeryVol. 142(4)
Openalex Percentile: Top 57%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of keratometric data by optical biometers and Scheimpflug camera in patients before lens surgery — S.V. Shukhaev, Y.M. Petrosyan, et al. · Fyodorov journal of ophthalmic surgery (2024) | TGRS Research Map | TGRS