Dual-scale study of pre-damage, water boundary conditions and frost interaction in concrete

Abstract This study investigated the interactive effects of pre-damage, water boundary conditions, and internal frost damage on concrete at dual-scale. The pre-damage included pre-cracking, which has not been studied experimentally before, and pre-compressive damage. Concrete specimens underwent pre-damage and had varied water boundary conditions during Freeze-Thaw Cycles (FTC). At the macro-scale, wedge-splitting tests combined with Digital Image Correlation (DIC) were conducted to assess post-FTC strength and fracture behaviour. At the meso-scale, X-ray CT scanning was employed to identify internal crack patterns. Results reveal that at the macro-scale, significant interaction between pre-damage and frost damage reduced splitting tensile strength compared to the internal frost damage alone. Besides, increased water exposure during FTCs reduced both splitting tensile strength and compressive strength, with a less pronounced reduction in splitting tensile strength. It also led to a diffuse crack pattern and increased tensile ductility. At the meso-scale, specimens subjected to the interactive effects of pre-damage and internal frost damage exhibited cracks along aggregate-cement interfaces and within the cement paste. Reference specimens displayed no internal cracks, while specimens exposed to only FTCs showed only cracks along aggregate-cement interfaces. Full submersion of specimens during FTCs induced more internal cracks than solely water on top. These findings on the interactions between pre-damage, water boundary conditions, and internal frost damage offer insight into the causes of frost damage, vital for the design and assessment of concrete structures in frost-prone environments. Furthermore, the results of these dual-scale tests can be used as a test case for the development of upscaling numerical models describing heat transfer and frost degradation in concrete.

Authors

Institutions

Publication Details

Journal
Materials and Structures
Published
2025-02-20
DOI
https://doi.org/10.1617/s11527-025-02599-9
Citations
1
Primary Topic
Concrete and Cement Materials Research
Type
article
Field-Weighted Citation Impact
0.95

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual-scale study of pre-damage, water boundary conditions and frost interaction in concrete

R. Kruse, Ralf Jänicke, Karin Lundgren, Lang-Zi Chang et al.
1 citations
Materials and Structures
Concrete and Cement Materials Research
0.95
article

Dual-scale study of pre-damage, water boundary conditions and frost interaction in concrete

R. Kruse, Ralf Jänicke, Karin Lundgren, Lang-Zi Chang, Katja Frid
article en
1 citations

Abstract

Abstract This study investigated the interactive effects of pre-damage, water boundary conditions, and internal frost damage on concrete at dual-scale. The pre-damage included pre-cracking, which has not been studied experimentally before, and pre-compressive damage. Concrete specimens underwent pre-damage and had varied water boundary conditions during Freeze-Thaw Cycles (FTC). At the macro-scale, wedge-splitting tests combined with Digital Image Correlation (DIC) were conducted to assess post-FTC strength and fracture behaviour. At the meso-scale, X-ray CT scanning was employed to identify internal crack patterns. Results reveal that at the macro-scale, significant interaction between pre-damage and frost damage reduced splitting tensile strength compared to the internal frost damage alone. Besides, increased water exposure during FTCs reduced both splitting tensile strength and compressive strength, with a less pronounced reduction in splitting tensile strength. It also led to a diffuse crack pattern and increased tensile ductility. At the meso-scale, specimens subjected to the interactive effects of pre-damage and internal frost damage exhibited cracks along aggregate-cement interfaces and within the cement paste. Reference specimens displayed no internal cracks, while specimens exposed to only FTCs showed only cracks along aggregate-cement interfaces. Full submersion of specimens during FTCs induced more internal cracks than solely water on top. These findings on the interactions between pre-damage, water boundary conditions, and internal frost damage offer insight into the causes of frost damage, vital for the design and assessment of concrete structures in frost-prone environments. Furthermore, the results of these dual-scale tests can be used as a test case for the development of upscaling numerical models describing heat transfer and frost degradation in concrete.

Materials and StructuresVol. 58(2)
Malmö University (SE), Chalmers University of Technology (SE), Technische Universität Braunschweig (DE)
Deutsche Forschungsgemeinschaft, Svenska Forskningsrådet Formas, Chalmers Tekniska Högskola, Vetenskapsrådet, Trafikverket
Openalex Percentile: Top 29%
Concrete and Cement Materials Research
0.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.