Estimation of contrast agents using a 2-dimensional photon counting CT detector combined with MPPC and YGAG scintillator array
The potential of photon-counting (PC) detectors in medical CT imaging is supported by their ability to count individual photons and measure their energy simultaneously, enabling multi-energy imaging with adjustable energy settings that enhance diagnostic accuracy. Contrast-enhanced CT imaging further improves diagnostic performance by allowing differentiation based on the distinct energy-dependent attenuation profiles of each contrast agent. The development of PCCT, consisting of the multi-pixel photon counter (MPPC) array and the yttrium-gadolinium-aluminum-gallium garnet (YGAG) scintillator array, has been expanded from a 1-dimensional to a 2-dimensional detector, thereby reducing the imaging time and enhancing temporal imaging resolution. The 2-dimensional PCCT uses a 256-channel pixel array (with 1 × 1 mm 2 for each pixel size), configured as 16 × 16 pixels. Signals from this array are processed by four large-scale integrated circuit boards, each handling 64 channels with six energy thresholds and capable of ultra-fast analog and digital signal processing exceeding 10 MHz per channel. CT imaging was performed on both non-mixture and mixture samples containing iodine and gadolinium using the 2-dimensional PCCT system. Concentration estimation from multiple-energy CT image data was performed, and a 3-dimensional concentration mapping for both non-mixture and mixture samples was achieved with a concentration accuracy of 0.2–1.8 mg/mL, demonstrating the capability of material discrimination in mixture sample. Furthermore, a preliminary demonstration of dynamical imaging using the 2-dimensional PCCT system was conducted. The temporal changes in quantitative data from multiple time-point images were successfully obtained, demonstrating the potential of the system for future dynamic clinical imaging applications, such as assessing blood flow and vessel dynamics.
Authors
- M. Sagisaka (ORCID: https://orcid.org/0000-0002-6781-3060)
- Satoshi Kobayashi (ORCID: https://orcid.org/0000-0001-7759-399X)
- Kazuhiro Murakami (ORCID: https://orcid.org/0000-0003-1759-9542)
- Hiroki Kawashima (ORCID: https://orcid.org/0000-0003-1223-8756)
- Kenichiro Okumura (ORCID: https://orcid.org/0000-0001-8131-7584)
- Daichi Sato (ORCID: https://orcid.org/0000-0002-6055-9987)
- Takahiro Tomoda
- J. Kataoka (ORCID: https://orcid.org/0000-0003-2819-6415)
- S. Terazawa
- M. Arimoto (ORCID: https://orcid.org/0000-0003-1250-7872)
- F. Lucyana (ORCID: https://orcid.org/0009-0006-8426-5736)
- Satoshi Shiota
- Ayumi Ishiguro
Institutions
- Kanazawa University (JP)
- Waseda University (JP)
- Ono Pharmaceutical (Japan) (JP)
Publication Details
- Journal
- Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
- Published
- 2025-02-20
- DOI
- https://doi.org/10.1016/j.nima.2025.170319
- Primary Topic
- Advanced X-ray and CT Imaging
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Naito Foundation
- Uehara Memorial Foundation
- Casio Science Promotion Foundation
- Murata Science Foundation
- Japan Society for the Promotion of Science
- Japan Science and Technology Agency
- Exploratory Research for Advanced Technology