A Novel Puma Optimizer Based TID Controller for Load Frequency Control

This paper presents the Puma Optimizer (PO) algorithm, a novel approach to the load frequency control problem. The proposed PO algorithm optimizes the gain parameters of the tilt-integral-derivative (TID) controller used for load frequency control in a two-area interconnected power system with a PV system. In this study, the proposed PO algorithm for optimizing the TID controller was compared with ImRSA, RSA, MGWO-CS and PDO algorithms, which were previously published in the literature. In the optimization of the TID controller's gain parameters based on the ITAE metric, the proposed PO algorithm achieved the best performance with a value of 0.7441, followed by ImRSA with 0.8239, RSA with 0.9251, MGWO-CS with 0.9203 and PDO with 0.8108. The performance of the optimized TID controller was evaluated based on the system's frequency response to a 0.1 p.u load disturbance in both areas. According to the simulation results obtained, it was observed that the proposed PO algorithm provided the fastest settling time and the minimum overshoot and undershoot values in the frequency response of the system in both areas and the tie-line against load changes.

Authors

Institutions

Publication Details

Published
2024-12-04
DOI
https://doi.org/10.1109/gec61857.2024.10881981
Citations
1
Primary Topic
Advanced Control Systems Design
Type
article
Field-Weighted Citation Impact
0.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Puma Optimizer Based TID Controller for Load Frequency Control

Cenk Andiç, Belgin Emre Türkay, Ali Öztürk, Esra Aydın
1 citations
Advanced Control Systems Design
0.33
article

A Novel Puma Optimizer Based TID Controller for Load Frequency Control

Cenk Andiç, Belgin Emre Türkay, Ali Öztürk, Esra Aydın
article en
1 citations

Abstract

This paper presents the Puma Optimizer (PO) algorithm, a novel approach to the load frequency control problem. The proposed PO algorithm optimizes the gain parameters of the tilt-integral-derivative (TID) controller used for load frequency control in a two-area interconnected power system with a PV system. In this study, the proposed PO algorithm for optimizing the TID controller was compared with ImRSA, RSA, MGWO-CS and PDO algorithms, which were previously published in the literature. In the optimization of the TID controller's gain parameters based on the ITAE metric, the proposed PO algorithm achieved the best performance with a value of 0.7441, followed by ImRSA with 0.8239, RSA with 0.9251, MGWO-CS with 0.9203 and PDO with 0.8108. The performance of the optimized TID controller was evaluated based on the system's frequency response to a 0.1 p.u load disturbance in both areas. According to the simulation results obtained, it was observed that the proposed PO algorithm provided the fastest settling time and the minimum overshoot and undershoot values in the frequency response of the system in both areas and the tie-line against load changes.

Istanbul Technical University (TR), Düzce Üniversitesi (TR)
Affordable and clean energy
Openalex Percentile: Top 36%
Advanced Control Systems Design
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Novel Puma Optimizer Based TID Controller for Load Frequency Control — Cenk Andiç, Belgin Emre Türkay, et al. · (2024) | TGRS Research Map | TGRS