4D Vital Sign Detection Based on a 24GHz 2T4R MIMO Radar System

A 4D vital sign detection technique is proposed in this paper. This method leverages the angle detection capabilities of MIMO radar and the distance sensing capabilities of FMCW radar. It tracks detailed heart and chest movements in time domain by assessing cardiac signals, thus completing the task of 3D spatial and 1D temporal vital sign detection. The proposed technique can acquire targets within a very narrow distance range and accurately locate the heart position. Additionally, a FMCW 2T4R MIMO radar prototype was designed and fabricated for experimental validation. Overnight experiments demonstrated that this method effectively locates the heart in various sleep postures, including supine, lateral, and prone positions. The effective overnight heart rate detection time exceeded $92 \%$, with an average detection error of 1.5 bpm. Compared to traditional beamforming methods, this approach accurately locates the heart while achieving medical-grade precision in heart rate detection, offering significant potential for further cardiopulmonary chronic disease analysis.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/apcap62011.2024.10881861
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

4D Vital Sign Detection Based on a 24GHz 2T4R MIMO Radar System

Jingyun Lu, Changzhan Gu, Yuchen Li
Non-Invasive Vital Sign Monitoring
article

4D Vital Sign Detection Based on a 24GHz 2T4R MIMO Radar System

Jingyun Lu, Changzhan Gu, Yuchen Li
article en

Abstract

A 4D vital sign detection technique is proposed in this paper. This method leverages the angle detection capabilities of MIMO radar and the distance sensing capabilities of FMCW radar. It tracks detailed heart and chest movements in time domain by assessing cardiac signals, thus completing the task of 3D spatial and 1D temporal vital sign detection. The proposed technique can acquire targets within a very narrow distance range and accurately locate the heart position. Additionally, a FMCW 2T4R MIMO radar prototype was designed and fabricated for experimental validation. Overnight experiments demonstrated that this method effectively locates the heart in various sleep postures, including supine, lateral, and prone positions. The effective overnight heart rate detection time exceeded $92 \%$, with an average detection error of 1.5 bpm. Compared to traditional beamforming methods, this approach accurately locates the heart while achieving medical-grade precision in heart rate detection, offering significant potential for further cardiopulmonary chronic disease analysis.

Shanghai Jiao Tong University (CN)
Affordable and clean energy
Openalex Percentile: Top 75%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

4D Vital Sign Detection Based on a 24GHz 2T4R MIMO Radar System — Jingyun Lu, Changzhan Gu, et al. · (2024) | TGRS Research Map | TGRS