Evaluation of Shear Bond Strength and Failure Modes of Lithium Disilicate Ceramic Veneering Material to Different High-Performance Polymers

This study assessed the shear bond strength (SBS) and failure modes of lithium disilicate ceramic veneering material to different high-performance polymers. Thirty-six square specimens measuring 7 × 7 × 2 ± 0.05 mm were prepared from pure polyetheretherketone (PEEK), Bio-high performance PEEK (BioHPP) and Trilor discs. Polymer specimens were air-borne abraded utilizing aluminum oxide particles, cleaned, and a bonding agent was applied (visio. link). The veneering LDC material (3 × 2 mm) was milled, hydrofluoric acid etched (9.5%) and primed (Clearfil ceramic). The LDC was bonded to the polymer specimens using dual-cured resin cement (Panavia V5) and light polymerized. The bonded specimens were subjected to 5000 cycles of physiological aging by thermocycling, and the SBS test was performed in a universal testing machine at 0.5 mm/min cross-head speed. The debonded specimens were analyzed to determine the primary bond failure sites (adhesive, mixed or cohesive). Data analysis was performed using one-way ANOVA and a post hoc Tukey test (α ≤ 0.05). The BioHPP material demonstrated the highest SBS values (23.94 ± 1.43 MPa), and the Trilor group recorded the lowest SBS values (17.09 ± 1.07 MPa). The PEEK group showed a mean SBS of 21.21 ± 1.51 MPa. The SBS comparison showed significant variations across all material groups (<i>p</i> < 0.001). Regarding failure modes, adhesive failure was observed in 40% of BioHPP and PEEK specimens and 90% of Trilor specimens. The cohesive failure occurred in 50% of PEEK and 30% of BioHPP specimens, while the Trilor specimens showed no cohesive failure. Mixed failures were reported in 30% of BioHPP and 10% of PEEK and Trilor specimens. The BioHPP material demonstrated high SBS followed by PEEK and Trilor. The SBS between the tested materials was statistically significant. However, the SBS of the tested implant framework materials was above the limit stipulated by the ISO 10477 standard (5 MPa) and the clinically acceptable range of 10-12 MPa.

Authors

Institutions

Publication Details

Journal
Polymers
Published
2025-02-20
DOI
https://doi.org/10.3390/polym17050554
Citations
4
Primary Topic
Advanced ceramic materials synthesis
Type
article
Field-Weighted Citation Impact
2.91
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Shear Bond Strength and Failure Modes of Lithium Disilicate Ceramic Veneering Material to Different High-Performance Polymers

Heba Wageh Abozaed, Rawan N. AlKahtani, Nawaf Labban, Refal Albaijan et al.
4 citations
Polymers
Advanced ceramic materials synthesis
2.91
article

Evaluation of Shear Bond Strength and Failure Modes of Lithium Disilicate Ceramic Veneering Material to Different High-Performance Polymers

Heba Wageh Abozaed, Rawan N. AlKahtani, Nawaf Labban, Refal Albaijan, Nada Y. Alturki, Sarah M. Alnafaiy, Khulud Al-Aali, Jomana E. Alenezi
article en
4 citations

Abstract

This study assessed the shear bond strength (SBS) and failure modes of lithium disilicate ceramic veneering material to different high-performance polymers. Thirty-six square specimens measuring 7 × 7 × 2 ± 0.05 mm were prepared from pure polyetheretherketone (PEEK), Bio-high performance PEEK (BioHPP) and Trilor discs. Polymer specimens were air-borne abraded utilizing aluminum oxide particles, cleaned, and a bonding agent was applied (visio. link). The veneering LDC material (3 × 2 mm) was milled, hydrofluoric acid etched (9.5%) and primed (Clearfil ceramic). The LDC was bonded to the polymer specimens using dual-cured resin cement (Panavia V5) and light polymerized. The bonded specimens were subjected to 5000 cycles of physiological aging by thermocycling, and the SBS test was performed in a universal testing machine at 0.5 mm/min cross-head speed. The debonded specimens were analyzed to determine the primary bond failure sites (adhesive, mixed or cohesive). Data analysis was performed using one-way ANOVA and a post hoc Tukey test (α ≤ 0.05). The BioHPP material demonstrated the highest SBS values (23.94 ± 1.43 MPa), and the Trilor group recorded the lowest SBS values (17.09 ± 1.07 MPa). The PEEK group showed a mean SBS of 21.21 ± 1.51 MPa. The SBS comparison showed significant variations across all material groups (<i>p</i> < 0.001). Regarding failure modes, adhesive failure was observed in 40% of BioHPP and PEEK specimens and 90% of Trilor specimens. The cohesive failure occurred in 50% of PEEK and 30% of BioHPP specimens, while the Trilor specimens showed no cohesive failure. Mixed failures were reported in 30% of BioHPP and 10% of PEEK and Trilor specimens. The BioHPP material demonstrated high SBS followed by PEEK and Trilor. The SBS between the tested materials was statistically significant. However, the SBS of the tested implant framework materials was above the limit stipulated by the ISO 10477 standard (5 MPa) and the clinically acceptable range of 10-12 MPa.

PolymersVol. 17(5)
Princess Nourah bint Abdulrahman University (SA), Prince Sattam Bin Abdulaziz University (SA), Mansoura University (EG), King Saud University (SA)
Openalex Percentile: Top 11%
Advanced ceramic materials synthesis
2.91
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.