A Portable Low-Overhead Self-Calibration System for K-Band Large-Scale Phased Array Transmission

A self-calibration method for phased array systems that does not require any RF equipment is proposed in this article. By using a radar source module to obtain the phase and amplitude matrix, and an algorithm to cancel the spatial path differences, the channel phase error matrix can be calculated. The proposed self-calibration method only takes 2 minutes in total, which is much faster than the REV-calibration test (20 minutes), and can achieve the same accuracy as REV calibration, within ±20 degrees. A high sensitive power detector is required for REV-calibration method of large phased arrays requires, otherwise the fitting results of REV-testing curves will leads to errors nearly ±20 degrees, reducing the accuracy. However, our method will not be affected by that.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/apcap62011.2024.10881419
Primary Topic
Antenna Design and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Portable Low-Overhead Self-Calibration System for K-Band Large-Scale Phased Array Transmission

Hongtao Xu, Botao Jiang, Yue Lin, Ruizhi Liu et al.
Antenna Design and Optimization
article

A Portable Low-Overhead Self-Calibration System for K-Band Large-Scale Phased Array Transmission

Hongtao Xu, Botao Jiang, Yue Lin, Ruizhi Liu, Shiping Zheng, Yun Wang
article en

Abstract

A self-calibration method for phased array systems that does not require any RF equipment is proposed in this article. By using a radar source module to obtain the phase and amplitude matrix, and an algorithm to cancel the spatial path differences, the channel phase error matrix can be calculated. The proposed self-calibration method only takes 2 minutes in total, which is much faster than the REV-calibration test (20 minutes), and can achieve the same accuracy as REV calibration, within ±20 degrees. A high sensitive power detector is required for REV-calibration method of large phased arrays requires, otherwise the fitting results of REV-testing curves will leads to errors nearly ±20 degrees, reducing the accuracy. However, our method will not be affected by that.

Fudan University (CN)
Technology Development
Affordable and clean energy
Openalex Percentile: Top 54%
Antenna Design and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.