A Novel and Accurate Phased Arrays Calibration Method by Combining Rotating-Element Electric-Field Vector and Amplitude Zeroing

A novel and accuracy phased array calibration method is presented in this paper. The method improves the rotating-element electric-field vector (REV) method, where the phase of each element is changed to obtain the varying amplitude and phase. During the amplitude calibration, a more concise and accurate calculation formula is proposed by rotating the vector. In addition, the phase error is calculated using the array element feed zeroing method. Simplicity of calculation and heightened precision can be achieved with the proposed rotating-element electric-field vector and amplitude zeroing (REV-AZ) method. Simulation experiments have shown that the REV-AZ method gives better calibration results.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/apcap62011.2024.10881651
Primary Topic
Antenna Design and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel and Accurate Phased Arrays Calibration Method by Combining Rotating-Element Electric-Field Vector and Amplitude Zeroing

Yuqian Yang, Zhiyong Luo, Da Hou, Lihui Wang et al.
Antenna Design and Optimization
article

A Novel and Accurate Phased Arrays Calibration Method by Combining Rotating-Element Electric-Field Vector and Amplitude Zeroing

Yuqian Yang, Zhiyong Luo, Da Hou, Lihui Wang, Xin Chen, Qiang Yang, Pengpeng Chen, Qiuhua Lin
article en

Abstract

A novel and accuracy phased array calibration method is presented in this paper. The method improves the rotating-element electric-field vector (REV) method, where the phase of each element is changed to obtain the varying amplitude and phase. During the amplitude calibration, a more concise and accurate calculation formula is proposed by rotating the vector. In addition, the phase error is calculated using the array element feed zeroing method. Simplicity of calculation and heightened precision can be achieved with the proposed rotating-element electric-field vector and amplitude zeroing (REV-AZ) method. Simulation experiments have shown that the REV-AZ method gives better calibration results.

Sun Yat-sen University (CN), China Academy of Space Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 54%
Antenna Design and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Novel and Accurate Phased Arrays Calibration Method by Combining Rotating-Element Electric-Field Vector and Amplitude Zeroing — Yuqian Yang, Zhiyong Luo, et al. · (2024) | TGRS Research Map | TGRS