Flexible Pressure Sensor Realized by a Chirped Fiber Bragg Grating Pair for Vital Signs Monitoring

A chirped Fabry-Perot interferometric (CFPI) pressure sensor based on two cascaded chirped 50-micron fiber Bragg gratings is proposed in this letter. Two packaging architectures of linear and circular structures using polydimethylsiloxane (PDMS) are demonstrated, while the latter one significantly improves pressure sensitivity owing to the annular light path in the FP cavity. Compared to the linear packaging configuration, the circular structure exhibits 3.438 times higher sensitivity in terms of wavelength drift with pressure, and a 21.307-fold increase in electrical signal sensitivity to pressure changes. Furthermore, the sensor was employed to measure pulse waveform on the wrist, and blood predictions were made using a convolutional neural network and long short-term memory (CNN-LSTM) model. As a result, the measurement errors for systolic blood pressure (SBP) and diastolic blood pressure (DBP) were −0.122 ± 2.781 mmHg and 0.051 ± 1.711 mmHg, respectively, which meet the standards set by the American Association for the Advancement of Medical Devices (AAMI). The proposed sensor employs a narrowband laser as light source and a photodiode for demodulation, showing the potential of miniaturization and cost reduction in sensing devices while maintaining high sensitivity. Additionally, the flexible sensor structure showcases the feasibility of a simple and highly accurate real-time medical wearable device, offering a promising solution for daily health monitoring.

Authors

Institutions

Publication Details

Journal
Journal of Lightwave Technology
Published
2025-02-20
DOI
https://doi.org/10.1109/jlt.2025.3543927
Citations
2
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flexible Pressure Sensor Realized by a Chirped Fiber Bragg Grating Pair for Vital Signs Monitoring

Zhengyong Liu, Dongxian Peng, Ziqi Liu, Pingping Wang et al.
2 citations
Journal of Lightwave Technology
Advanced Fiber Optic Sensors
1.46
article

Flexible Pressure Sensor Realized by a Chirped Fiber Bragg Grating Pair for Vital Signs Monitoring

Zhengyong Liu, Dongxian Peng, Ziqi Liu, Pingping Wang, Chang Liu
article en
2 citations

Abstract

A chirped Fabry-Perot interferometric (CFPI) pressure sensor based on two cascaded chirped 50-micron fiber Bragg gratings is proposed in this letter. Two packaging architectures of linear and circular structures using polydimethylsiloxane (PDMS) are demonstrated, while the latter one significantly improves pressure sensitivity owing to the annular light path in the FP cavity. Compared to the linear packaging configuration, the circular structure exhibits 3.438 times higher sensitivity in terms of wavelength drift with pressure, and a 21.307-fold increase in electrical signal sensitivity to pressure changes. Furthermore, the sensor was employed to measure pulse waveform on the wrist, and blood predictions were made using a convolutional neural network and long short-term memory (CNN-LSTM) model. As a result, the measurement errors for systolic blood pressure (SBP) and diastolic blood pressure (DBP) were −0.122 ± 2.781 mmHg and 0.051 ± 1.711 mmHg, respectively, which meet the standards set by the American Association for the Advancement of Medical Devices (AAMI). The proposed sensor employs a narrowband laser as light source and a photodiode for demodulation, showing the potential of miniaturization and cost reduction in sensing devices while maintaining high sensitivity. Additionally, the flexible sensor structure showcases the feasibility of a simple and highly accurate real-time medical wearable device, offering a promising solution for daily health monitoring.

Journal of Lightwave TechnologyVol. 43(10)
Sun Yat-sen University (CN), Southern Marine Science and Engineering Guangdong Laboratory (Guangzhou) (CN), Zhujiang Hospital (CN), Southern Marine Science and Engineering Guangdong Laboratory (Zhuhai) (CN), Southern Medical University (CN)
Openalex Percentile: Top 19%
Advanced Fiber Optic Sensors
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.