Dual Photoplethysmography Pulse Wave Velocity-Based Blood Pressure Prediction for Wearable Healthcare Internet of Things
The Internet of Things (IoT) is a modern means of communication and its integration with biosensing significantly enhanced the monitoring and sensing of human vital signs, with blood pressure (BP) emerging as a promising application within the healthcare IoT domain. This study introduces a real-time, machine learning (ML)-based 3-D printed wearable device for BP and heart rate (HR) estimation using an advanced bi-optical pulse-wave-velocity acquisition system (BOPAS), which employs a dual photoplethysmography with an IoT-integrated wireless architecture for remote healthcare monitoring. Unlike conventional approaches, the proposed architecture eliminates dependency on high-quality signals and computationally intensive ML models by directly demonstrating strong pulse wave velocity (PWV) and BP correlation (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${r} =0.96$ </tex-math></inline-formula> for systolic, 0.89 for diastolic). Moreover, it overcomes the limitations like pulse ejection period and real-time filtering delays found in existing PWV methods making it simpler, more accurate, and practical for real-time wearables. After evaluating 14 different ML models, support vector regressor (SVR) yielded the highest testing R-square (R2) scores, surpassing 0.9272 for systolic BP (SBP) and 0.7896 for diastolic BP (DBP). A trained SVR model is deployed on a custom made smartphone application and tested in real time, yielding a mean absolute error and standard deviation of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2.68\pm 1.61$ </tex-math></inline-formula> mmHg for SBP, <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2.94\pm 1.84$ </tex-math></inline-formula> mmHg for DBP, and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.81\pm 0.55$ </tex-math></inline-formula> beats per min for HR. Additionally, 90.1% of SBP samples and 85.0% of DBP samples exhibit absolute error less than 5 mmHg, demonstrating a promising results compared to the other approach.
Authors
- Sebin Kim
- Young‐Joon Kim (ORCID: https://orcid.org/0000-0003-3511-3438)
- M.A. Bhutta
Institutions
- Gachon University (KR)
Publication Details
- Journal
- IEEE Internet of Things Journal
- Published
- 2025-02-20
- DOI
- https://doi.org/10.1109/jiot.2025.3544290
- Citations
- 3
- Primary Topic
- Non-Invasive Vital Sign Monitoring
- Type
- article
- Field-Weighted Citation Impact
- 2.02
Funders
- Gachon University
- National Research Foundation of Korea