Analytical modeling of Nusselt number and friction factor for honeycomb-shaped artificial roughness in solar air heater

This research paper investigates the impact of honeycomb-shaped roughness on the thermo-hydraulic performance parameter (THPP), Nusselt number (Nu), and friction factor (FF) in the solar air heater (SAH). The investigation employs computational fluid dynamics (CFD) analysis and experimental validations, focusing on Reynolds numbers (Re, 3000–21000) as the operational parameter. The study explores key design parameters, including relative roughness height (e/D, 0.03–0.05), relative roughness pitch (P/e, 8–12), and the angle of attack (Ø, 90˚ −120˚). Validation of CFD results against experimental findings reveals a maximum Mean Absolute Percentage Error (MAPE) of 8.3 % for the FF and 9.8 % for the Nu, indicating strong agreement between CFD simulations and experimental observations. Key findings include a maximum THPP of 1.7 achieved at an (P/e) of 10, (e/D) of 0.04, and (Ø) of 120˚ with Re of 6000. Additionally, a maximum Nu of 140.65 is attained at an(P/e) of 10, (e/D) of 0.04, (Ø) of 120˚, and Re of 21000. The highest FF of 0.039 is recorded at an (P/e) of 9, (e/D) of 0.05, and (Ø) of 120˚ at Re of 6000. Regression analysis is employed to establish correlations for FF and Nu as functions of (Re) and honeycomb-shaped roughness parameters. Comparisons between the developed equations and CFD results indicate MAPE of 6.1 % for the FF and 4.7 % for the Nu, affirming the accuracy and reliability of the correlations in predicting frictional and heat transfer properties of the system. • Utilization of CFD analysis combined with experimental validations. • Optimization of design parameters for honeycomb roughness. • Establishment of equations for friction factor and Nusselt number.

Authors

Institutions

Publication Details

Journal
Next Materials
Published
2025-02-20
DOI
https://doi.org/10.1016/j.nxmate.2025.100529
Citations
6
Primary Topic
Heat Transfer Mechanisms
Type
article
Field-Weighted Citation Impact
4.28
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical modeling of Nusselt number and friction factor for honeycomb-shaped artificial roughness in solar air heater

Somar Rajeh Ghanem, Amit C. Bhosale
6 citations
Next Materials
Heat Transfer Mechanisms
4.28
article

Analytical modeling of Nusselt number and friction factor for honeycomb-shaped artificial roughness in solar air heater

Somar Rajeh Ghanem, Amit C. Bhosale
article en
6 citations

Abstract

This research paper investigates the impact of honeycomb-shaped roughness on the thermo-hydraulic performance parameter (THPP), Nusselt number (Nu), and friction factor (FF) in the solar air heater (SAH). The investigation employs computational fluid dynamics (CFD) analysis and experimental validations, focusing on Reynolds numbers (Re, 3000–21000) as the operational parameter. The study explores key design parameters, including relative roughness height (e/D, 0.03–0.05), relative roughness pitch (P/e, 8–12), and the angle of attack (Ø, 90˚ −120˚). Validation of CFD results against experimental findings reveals a maximum Mean Absolute Percentage Error (MAPE) of 8.3 % for the FF and 9.8 % for the Nu, indicating strong agreement between CFD simulations and experimental observations. Key findings include a maximum THPP of 1.7 achieved at an (P/e) of 10, (e/D) of 0.04, and (Ø) of 120˚ with Re of 6000. Additionally, a maximum Nu of 140.65 is attained at an(P/e) of 10, (e/D) of 0.04, (Ø) of 120˚, and Re of 21000. The highest FF of 0.039 is recorded at an (P/e) of 9, (e/D) of 0.05, and (Ø) of 120˚ at Re of 6000. Regression analysis is employed to establish correlations for FF and Nu as functions of (Re) and honeycomb-shaped roughness parameters. Comparisons between the developed equations and CFD results indicate MAPE of 6.1 % for the FF and 4.7 % for the Nu, affirming the accuracy and reliability of the correlations in predicting frictional and heat transfer properties of the system. • Utilization of CFD analysis combined with experimental validations. • Optimization of design parameters for honeycomb roughness. • Establishment of equations for friction factor and Nusselt number.

Next MaterialsVol. 8
Indian Institute of Technology Roorkee (IN)
Affordable and clean energy
Openalex Percentile: Top 6%
Heat Transfer Mechanisms
4.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analytical modeling of Nusselt number and friction factor for honeycomb-shaped artificial roughness in solar air heater — Somar Rajeh Ghanem, Amit C. Bhosale · Next Materials (2025) | TGRS Research Map | TGRS