Enhanced on-site testing of DC current transformers using improved EMD filtering and high-precision synchronization

The DC current transformer, which forms the foundation of the high-voltage DC transmission system, must be designed rationally and have accurate field testing. This study examines the causes of the faults in the field test system for the DC current transformer and suggests a closed-loop test technique for the field that builds upon empirical modal decomposition (EMD) filtering. The technique uses an 18-bit high-precision A/D acquisition and the EMD algorithm to filter out harmonics, which greatly increases the measurement accuracy of the test system. It also realizes the synchronous acquisition of the standard source analog quantity and the measured digital quantity through the high-precision synchronization module, which solves the error caused by the delay. The test findings indicate that the enhanced system removes data with significant inaccuracies in the standard value 6250A test, bringing the measured value closer to the standard value. Furthermore, a step source system was built and its accuracy and feasibility were confirmed by experiments for the purpose of measuring the transient step response of DC current transformers. The enhanced test equipment performs exceptionally well in transient and steady state tests and is highly valuable for engineering applications.

Authors

Publication Details

Journal
Mari Papel y Corrugado
Published
2025-02-20
DOI
https://doi.org/10.71442/mari2025-0002
Citations
3
Primary Topic
Magnetic Properties and Applications
Type
article
Field-Weighted Citation Impact
1.28
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced on-site testing of DC current transformers using improved EMD filtering and high-precision synchronization

Tianfu Huang, Xiang Wu, Chunguang Wang, Wu Zhiwu et al.
3 citations
Mari Papel y Corrugado
Magnetic Properties and Applications
1.28
article

Enhanced on-site testing of DC current transformers using improved EMD filtering and high-precision synchronization

Tianfu Huang, Xiang Wu, Chunguang Wang, Wu Zhiwu, Tu Yanzhao
article en
3 citations

Abstract

The DC current transformer, which forms the foundation of the high-voltage DC transmission system, must be designed rationally and have accurate field testing. This study examines the causes of the faults in the field test system for the DC current transformer and suggests a closed-loop test technique for the field that builds upon empirical modal decomposition (EMD) filtering. The technique uses an 18-bit high-precision A/D acquisition and the EMD algorithm to filter out harmonics, which greatly increases the measurement accuracy of the test system. It also realizes the synchronous acquisition of the standard source analog quantity and the measured digital quantity through the high-precision synchronization module, which solves the error caused by the delay. The test findings indicate that the enhanced system removes data with significant inaccuracies in the standard value 6250A test, bringing the measured value closer to the standard value. Furthermore, a step source system was built and its accuracy and feasibility were confirmed by experiments for the purpose of measuring the transient step response of DC current transformers. The enhanced test equipment performs exceptionally well in transient and steady state tests and is highly valuable for engineering applications.

Mari Papel y CorrugadoVol. 2025(1)
Openalex Percentile: Top 22%
Magnetic Properties and Applications
1.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.