Fabrications and Performance Test of ECal Modules in China for NICA-MPD Experiment

Electromagnetic Calorimeter (ECal), a subdetector of Multipurpose Detector (MPD), is designed to identify electrons, photons, and neutral hadrons produced in high-energy heavy-ion collisions at nuclotron-based ion collider facility (NICA) and measure their energies and positions. A Shashlyk-type sampling calorimeter composed of lead plates as absorbers and plastic scintillators arranged alternately was selected for ECal. Chinese MPD consortium is responsible for the development of 768 ECal modules which is $$1/3$$ of the whole ECal detector. In this report, the mass production process of ECal modules and a performance test system designed for the mass production will be presented. The uniformity of the ECal modules achieved based on cosmic ray test will be discussed. Preliminary results demonstrate the produced ECal modules met the design requirements, indicating the quality control in mass production is effective. These modules were delivered to the Joint Institute for Nuclear Research (JINR) at Dubna in March 2023, and will soon be installed on MPD detector for further commissioning.

Authors

Institutions

Publication Details

Journal
Moscow University Physics Bulletin
Published
2024-12-01
DOI
https://doi.org/10.3103/s0027134924700747
Citations
1
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.66
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fabrications and Performance Test of ECal Modules in China for NICA-MPD Experiment

Kun Hu, Yonghong Wang, C. Yang
1 citations
Moscow University Physics Bulletin
Particle Detector Development and Performance
0.66
article

Fabrications and Performance Test of ECal Modules in China for NICA-MPD Experiment

Kun Hu, Yonghong Wang, C. Yang
article en
1 citations

Abstract

Electromagnetic Calorimeter (ECal), a subdetector of Multipurpose Detector (MPD), is designed to identify electrons, photons, and neutral hadrons produced in high-energy heavy-ion collisions at nuclotron-based ion collider facility (NICA) and measure their energies and positions. A Shashlyk-type sampling calorimeter composed of lead plates as absorbers and plastic scintillators arranged alternately was selected for ECal. Chinese MPD consortium is responsible for the development of 768 ECal modules which is $$1/3$$ of the whole ECal detector. In this report, the mass production process of ECal modules and a performance test system designed for the mass production will be presented. The uniformity of the ECal modules achieved based on cosmic ray test will be discussed. Preliminary results demonstrate the produced ECal modules met the design requirements, indicating the quality control in mass production is effective. These modules were delivered to the Joint Institute for Nuclear Research (JINR) at Dubna in March 2023, and will soon be installed on MPD detector for further commissioning.

Moscow University Physics BulletinVol. 79(S1)
Institut des Sciences Moléculaires (FR), Institute of Particle Physics (CA)
Openalex Percentile: Top 13%
Particle Detector Development and Performance
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.