Comparison of Temperature Changes during Implant Osteotomy: Conventional, Single, and Osseodensification Drilling

<b>Purpose:</b> This study compared temperature changes during implant osteotomies using osseodensification drilling (OD), conventional drilling, (CD) and single drilling (SD) protocols on artificial bone blocks of varying densities. <b>Methods:</b> In this <i>in vitro</i> study, 240 osteotomies were performed (80 each for CD, SD, and OD protocols) across four bone densities (D1, D2, D3, and D4) and two drilling speeds (800 rpm and 1600 rpm). A drill length of 12 mm and diameter of 3.3 mm were used under irrigated conditions. Temperature changes were measured using an infrared thermal camera, noting the initial temperature (T<sub>0</sub>), the maximum temperature reached (T<sub>1</sub>), and the temperature change (ΔT) before and after each osteotomy, with comparisons drawn among the three protocols. <b>Results:</b> Significant differences in ΔT were observed between the CD and SD protocols across all bone densities and speeds. The CD protocol showed lower ΔT levels at 1600 rpm compared to 800 rpm, whereas the SD protocol showed significantly higher mean ΔT levels at 1600 rpm. For the OD protocol, there was no significant difference in ΔT between the two speeds for D1-D3 densities; however, a significant increase in ΔT was recorded at 1600 rpm for D4. Moreover, the CD protocol consistently yielded the lowest temperature increases in denser bones (D1-D2) at both speeds, while the OD protocol had lower ΔT in less dense bones (D4). <b>Conclusions:</b> The CD protocol consistently achieved lower temperature changes, particularly in denser bones, compared to the SD and OD protocols. The OD protocol, meanwhile, was more effective at reducing temperature increases in less-dense bones.

Authors

Institutions

Publication Details

Journal
International Journal of Medical Sciences
Published
2025-02-18
DOI
https://doi.org/10.7150/ijms.105544
Citations
4
Primary Topic
Infrared Thermography in Medicine
Type
article
Field-Weighted Citation Impact
5.44
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Temperature Changes during Implant Osteotomy: Conventional, Single, and Osseodensification Drilling

Gülsüm Ak, Zeynep Afra Akbıyık Az
4 citations
International Journal of Medical Sciences
Infrared Thermography in Medicine
5.44
article

Comparison of Temperature Changes during Implant Osteotomy: Conventional, Single, and Osseodensification Drilling

Gülsüm Ak, Zeynep Afra Akbıyık Az
article en
4 citations

Abstract

<b>Purpose:</b> This study compared temperature changes during implant osteotomies using osseodensification drilling (OD), conventional drilling, (CD) and single drilling (SD) protocols on artificial bone blocks of varying densities. <b>Methods:</b> In this <i>in vitro</i> study, 240 osteotomies were performed (80 each for CD, SD, and OD protocols) across four bone densities (D1, D2, D3, and D4) and two drilling speeds (800 rpm and 1600 rpm). A drill length of 12 mm and diameter of 3.3 mm were used under irrigated conditions. Temperature changes were measured using an infrared thermal camera, noting the initial temperature (T<sub>0</sub>), the maximum temperature reached (T<sub>1</sub>), and the temperature change (ΔT) before and after each osteotomy, with comparisons drawn among the three protocols. <b>Results:</b> Significant differences in ΔT were observed between the CD and SD protocols across all bone densities and speeds. The CD protocol showed lower ΔT levels at 1600 rpm compared to 800 rpm, whereas the SD protocol showed significantly higher mean ΔT levels at 1600 rpm. For the OD protocol, there was no significant difference in ΔT between the two speeds for D1-D3 densities; however, a significant increase in ΔT was recorded at 1600 rpm for D4. Moreover, the CD protocol consistently yielded the lowest temperature increases in denser bones (D1-D2) at both speeds, while the OD protocol had lower ΔT in less dense bones (D4). <b>Conclusions:</b> The CD protocol consistently achieved lower temperature changes, particularly in denser bones, compared to the SD and OD protocols. The OD protocol, meanwhile, was more effective at reducing temperature increases in less-dense bones.

International Journal of Medical SciencesVol. 22(6)
Istanbul University (TR)
Openalex Percentile: Top 5%
Infrared Thermography in Medicine
5.44
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.