Data Calibration of Binocular Vision Pulse Acquisition System Based on CNN+GRU

To address potential calibration errors that may occur during the acquisition of pulse images based on binocular vision, as well as inaccuracies in three-dimensional(3D) reconstruction, a data calibration model based on Convolutional Neural Networks and Gated Recurrent Units (CNN+GRU) is proposed as a method of calibrating the pulse wave data acquired by the binocular vision pulse acquisition system. The CNN is used to retrieve the error characteristics of the pulse wave and the GRU is used to learn the time-dependent characteristics of the monitoring data and the occurrence of data drift. The precise data produced by the laser profile sensor serves as a reference for calibration. Finally, the fusion module is used to collect the calibration data. The results of both the calibration and ablation experiments show that the calibration model and its component modules are effective.

Authors

Institutions

Publication Details

Published
2024-10-18
DOI
https://doi.org/10.1145/3711129.3711289
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Data Calibration of Binocular Vision Pulse Acquisition System Based on CNN+GRU

Xiangling Wang, Yongxin Chou, Dongmei Lin, Fuming Chen et al.
Non-Invasive Vital Sign Monitoring
article

Data Calibration of Binocular Vision Pulse Acquisition System Based on CNN+GRU

Xiangling Wang, Yongxin Chou, Dongmei Lin, Fuming Chen, Y. Gan
article en

Abstract

To address potential calibration errors that may occur during the acquisition of pulse images based on binocular vision, as well as inaccuracies in three-dimensional(3D) reconstruction, a data calibration model based on Convolutional Neural Networks and Gated Recurrent Units (CNN+GRU) is proposed as a method of calibrating the pulse wave data acquired by the binocular vision pulse acquisition system. The CNN is used to retrieve the error characteristics of the pulse wave and the GRU is used to learn the time-dependent characteristics of the monitoring data and the occurrence of data drift. The precise data produced by the laser profile sensor serves as a reference for calibration. Finally, the fusion module is used to collect the calibration data. The results of both the calibration and ablation experiments show that the calibration model and its component modules are effective.

Suzhou University of Technology (CN), Lanzhou University of Technology (CN), Chinese People's Liberation Army (CN)
Government of Jiangsu Province, Qinglan Project of Jiangsu Province of China, Science and Technology Program of Gansu Province
Openalex Percentile: Top 75%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.