Development and Validation of a Noninvasive Diffuse Reflectance Spectroscopic Method for Bilirubin Estimation in Neonates

Jaundice due to excess bilirubin buildup in neonates remains an alarming problem, especially during the very first week of postnatal life. The common method of measuring total serum bilirubin (TSB) levels involves invasive blood testing, which is time-consuming and uncomfortable for neonates. While noninvasive transcutaneous bilirubinometers (TcB) are available, that often lack accuracy due to interference from other biological chromophores. This study aims to improve bilirubin assessment by developing a noninvasive system that uses diffuse reflectance spectroscopy and a novel algorithm accounting for chromophores like melanin and hemoglobin. Focusing on the sternum as the measurement site, spectra are collected from 285 newborns. Using the proposed algorithm, the bilirubin concentration is calculated at 450, 460, and 470 nm. Compared to TSB levels, the proposed method demonstrated strong accuracy with an average bias of -0.10 mg/dL and narrower limits of agreement of 4.85 mg/dL at 470 nm.

Authors

Institutions

Publication Details

Journal
Journal of Biophotonics
Published
2025-02-20
DOI
https://doi.org/10.1002/jbio.202400505
Citations
1
Primary Topic
Neonatal Health and Biochemistry
Type
article
Field-Weighted Citation Impact
3.49
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of a Noninvasive Diffuse Reflectance Spectroscopic Method for Bilirubin Estimation in Neonates

Ashok Chandrasekaran, R. Chitra, Subash Sundar, Shanthi Prince
1 citations
Journal of Biophotonics
Neonatal Health and Biochemistry
3.49
article

Development and Validation of a Noninvasive Diffuse Reflectance Spectroscopic Method for Bilirubin Estimation in Neonates

Ashok Chandrasekaran, R. Chitra, Subash Sundar, Shanthi Prince
article en
1 citations

Abstract

Jaundice due to excess bilirubin buildup in neonates remains an alarming problem, especially during the very first week of postnatal life. The common method of measuring total serum bilirubin (TSB) levels involves invasive blood testing, which is time-consuming and uncomfortable for neonates. While noninvasive transcutaneous bilirubinometers (TcB) are available, that often lack accuracy due to interference from other biological chromophores. This study aims to improve bilirubin assessment by developing a noninvasive system that uses diffuse reflectance spectroscopy and a novel algorithm accounting for chromophores like melanin and hemoglobin. Focusing on the sternum as the measurement site, spectra are collected from 285 newborns. Using the proposed algorithm, the bilirubin concentration is calculated at 450, 460, and 470 nm. Compared to TSB levels, the proposed method demonstrated strong accuracy with an average bias of -0.10 mg/dL and narrower limits of agreement of 4.85 mg/dL at 470 nm.

Journal of BiophotonicsVol. 18(5)
SRM Institute of Science and Technology (IN)
Openalex Percentile: Top 12%
Neonatal Health and Biochemistry
3.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.