An experimental study on subharmonic-aided pressure estimation with commercial scanners

This study evaluates the performance of subharmonic-aided pressure estimation (SHAPE) with ultrasound contrast agents using data obtained from calibration procedures. A commercial scanner of ultrasonography (GE Healthcare Logiq E20, Wuxi, China) was used to perform SHAPE on a flowing contrast agent (Sonazoid) in a phantom setup under controlled microbubble stability and flow velocity conditions. Subharmonic time-intensity curves were collected during the SHAPE calibration procedure for analysis. Subharmonic amplitude of diluted contrast agents exhibited a time-dependent decline but was not affected by velocity. SHAPE sensitivity was measured through reciprocal pressurizing and depressurizing sequences to mitigate the effect of subharmonic decline over time. A wide range of mechanical index (MI) levels within the steady growth phase of the calibration curve showed higher SHAPE sensitivity compared to the traditionally recommended "optimal" MI at the maximum slope. The approximate maximum SHAPE sensitivity was -0.04 dB/mm Hg. Subharmonic amplitude was linearly correlated with pressure at a range of MI levels (R2 > 0.9, p < 0.05) but showed significant variations (approximately 2 dB standard deviation) in the time series. The lowered sensitivity compared to previous reports, combined with the substantial variation in subharmonic amplitude, raises concerns about the accuracy and consistency of SHAPE in clinical applications.

Authors

Institutions

Publication Details

Journal
The Journal of the Acoustical Society of America
Published
2025-02-01
DOI
https://doi.org/10.1121/10.0035574
Citations
1
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An experimental study on subharmonic-aided pressure estimation with commercial scanners

Xiaodong Han, Yifan Dong, Zhitong Ge, Wei Jiang et al.
1 citations
The Journal of the Acoustical Society of America
Ultrasound and Hyperthermia Applications
0.67
article

An experimental study on subharmonic-aided pressure estimation with commercial scanners

Xiaodong Han, Yifan Dong, Zhitong Ge, Wei Jiang, Ying Wang, Li Zhang, Dan Chen, Yahong Wang, Yao Chen, Xin Wang, Jianchu Li, Xiao Yang, Ji-feng Tian
article en
1 citations

Abstract

This study evaluates the performance of subharmonic-aided pressure estimation (SHAPE) with ultrasound contrast agents using data obtained from calibration procedures. A commercial scanner of ultrasonography (GE Healthcare Logiq E20, Wuxi, China) was used to perform SHAPE on a flowing contrast agent (Sonazoid) in a phantom setup under controlled microbubble stability and flow velocity conditions. Subharmonic time-intensity curves were collected during the SHAPE calibration procedure for analysis. Subharmonic amplitude of diluted contrast agents exhibited a time-dependent decline but was not affected by velocity. SHAPE sensitivity was measured through reciprocal pressurizing and depressurizing sequences to mitigate the effect of subharmonic decline over time. A wide range of mechanical index (MI) levels within the steady growth phase of the calibration curve showed higher SHAPE sensitivity compared to the traditionally recommended "optimal" MI at the maximum slope. The approximate maximum SHAPE sensitivity was -0.04 dB/mm Hg. Subharmonic amplitude was linearly correlated with pressure at a range of MI levels (R2 > 0.9, p < 0.05) but showed significant variations (approximately 2 dB standard deviation) in the time series. The lowered sensitivity compared to previous reports, combined with the substantial variation in subharmonic amplitude, raises concerns about the accuracy and consistency of SHAPE in clinical applications.

The Journal of the Acoustical Society of AmericaVol. 157(2)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Peking Union Medical College Hospital (CN)
Openalex Percentile: Top 35%
Ultrasound and Hyperthermia Applications
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.