Analysis of the causes of failure in the rubber lining of the concentrated hydrochloric acid storage tank at a nuclear power plant

Abstract The rubber lining in a condensate polishing system of a nuclear power plant exhibited significant blistering and cracking shortly after the operation, posing a safety risk to the chlorine storage tank. Extensive analysis, including thermal gravimetric analysis, infrared spectroscopy, mechanical testing, and scanning electron microscopy, was conducted to assess the rubber lining thoroughly. Subsequently, the lining underwent a 72-hour immersion test in 31 % hydrochloric acid at 50°C to evaluate its performance. The results revealed that the rubber content of the lining was 55.7 %, with natural rubber as the material type. Although there was minimal change in mass following hydrochloric acid exposure, both tensile strength and hardness were compromised. Macroscopic and microscopic observations suggested that improper operation during mixing or curing processes led to uneven distribution of components within the lining, allowing for hydrochloric acid penetration through defects and subsequent blistering.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-02-01
DOI
https://doi.org/10.1088/1742-6596/2951/1/012041
Primary Topic
Risk and Safety Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the causes of failure in the rubber lining of the concentrated hydrochloric acid storage tank at a nuclear power plant

Qishu Fang, Weiguang Li, Kewei Yang, Kun Yang et al.
Journal of Physics Conference Series
Risk and Safety Analysis
article

Analysis of the causes of failure in the rubber lining of the concentrated hydrochloric acid storage tank at a nuclear power plant

Qishu Fang, Weiguang Li, Kewei Yang, Kun Yang, Yang Lv
article en

Abstract

Abstract The rubber lining in a condensate polishing system of a nuclear power plant exhibited significant blistering and cracking shortly after the operation, posing a safety risk to the chlorine storage tank. Extensive analysis, including thermal gravimetric analysis, infrared spectroscopy, mechanical testing, and scanning electron microscopy, was conducted to assess the rubber lining thoroughly. Subsequently, the lining underwent a 72-hour immersion test in 31 % hydrochloric acid at 50°C to evaluate its performance. The results revealed that the rubber content of the lining was 55.7 %, with natural rubber as the material type. Although there was minimal change in mass following hydrochloric acid exposure, both tensile strength and hardness were compromised. Macroscopic and microscopic observations suggested that improper operation during mixing or curing processes led to uneven distribution of components within the lining, allowing for hydrochloric acid penetration through defects and subsequent blistering.

Journal of Physics Conference SeriesVol. 2951(1)
State Nuclear Power Technology Company (China) (CN), Fiberhome Technology Group (China) (CN)
Openalex Percentile: Top 96%
Risk and Safety Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.