Closed-loop pulse shaping with <1ps resolution over >2ns records using STILETTO combined with Three Phase Spectral Interferometry (3PSI)

The ability to arbitrarily shape pulses in both intensity and wavelength vs. time with fine resolution over long records offers new capability for experiments involving laser interactions with matter.We demonstrate a novel optical recorder (3PSI) that is capable of recording optical amplitude and phase over >2ns records with <1ps resolution in a single shot.Three spectral interferograms are simultaneously recorded using three high resolution VIPA spectrometers.By avoiding approximations in the phase retrieval, waveforms can be measured with high fidelity.We applied 3PSI to our previously demonstrated STILETTO wavelength and amplitude optical pulse shaper to precisely closed-loop shape optical pulses in amplitude and apply arbitrary wavelength vs time patterns.

Authors

Institutions

Publication Details

Journal
OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)
Published
2025-02-07
Primary Topic
Nuclear Physics and Applications
Type
article
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Closed-loop pulse shaping with <1ps resolution over >2ns records using STILETTO combined with Three Phase Spectral Interferometry (3PSI)

R D Muir
OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)
Nuclear Physics and Applications
article

Closed-loop pulse shaping with <1ps resolution over >2ns records using STILETTO combined with Three Phase Spectral Interferometry (3PSI)

R D Muir
article en

Abstract

The ability to arbitrarily shape pulses in both intensity and wavelength vs. time with fine resolution over long records offers new capability for experiments involving laser interactions with matter.We demonstrate a novel optical recorder (3PSI) that is capable of recording optical amplitude and phase over >2ns records with <1ps resolution in a single shot.Three spectral interferograms are simultaneously recorded using three high resolution VIPA spectrometers.By avoiding approximations in the phase retrieval, waveforms can be measured with high fidelity.We applied 3PSI to our previously demonstrated STILETTO wavelength and amplitude optical pulse shaper to precisely closed-loop shape optical pulses in amplitude and apply arbitrary wavelength vs time patterns.

OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)
Lawrence Livermore National Laboratory (US)
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.