Performance of Unmodified Mechanical Ventilators With 2% Hydrogen Gas Mixtures
<b>Background:</b> Molecular hydrogen (H<sub>2</sub>) is a breathable gas that has been shown to have anti-oxidative, anti-inflammatory, and anti-apoptotic properties that may positively impact ischemia-reperfusion injury. The provision of 2% H<sub>2</sub> through unmodified mechanical ventilators may facilitate the clinical translation of H<sub>2</sub> as a therapeutic in critical illness. The effect of 2% H<sub>2</sub> on ventilator performance is unknown. <b>Methods:</b> Unmodified Maquet Servo-i, Maquet Servo-u, Dräger Evita Infinity V500, and Dräger Evita Babylog VN500 ventilators from clinical stock were tested in an experimental closed system using certified, premixed air and O<sub>2</sub> containing 2% H<sub>2</sub> gas. Wall air and O<sub>2</sub> supply were used as control. Ventilator settings were varied across the spectrum of neonatal to adult settings. End points included (1) difference between set and delivered tidal volume (V<sub>T</sub>) (Douglas method), (2) difference between set versus delivered O<sub>2</sub> concentration, (3) delivered H<sub>2</sub> concentration (gas chromatography), and (4) ventilator pre-use check malfunction. Correlation between set and measured end points were quantified by linear regression analysis and bias by Bland-Altman analysis. <b>Results:</b> During H<sub>2</sub> administration, the average bias in measured versus set V<sub>T</sub> was within ± 10% for all ventilators except for the Babylog VN500, which exhibited an average bias of -89.2% (95% CI -107.0 to -71.3). The average bias in measured F<sub>IO<sub>2</sub></sub> was within ± 10% of set for all ventilators. Except for the Babylog VN500, all ventilators passed the pre-use check. <b>Conclusions:</b> Unmodified Servo-i, Servo-u, and Evita V500 ventilators deliver 2% H<sub>2</sub> mixtures with acceptable accuracy in V<sub>T</sub> and F<sub>IO<sub>2</sub></sub>. The Babylog VN500, which uses hot-wire anometry and a higher set operating temperature, exhibits unacceptably inaccurate delivery of V<sub>T</sub> with H<sub>2</sub> mixtures.
Authors
- Marc Anders (ORCID: https://orcid.org/0000-0003-0272-4136)
- Richard Nguyen (ORCID: https://orcid.org/0000-0003-2453-3461)
- Kristen Sack
- John N. Kheir (ORCID: https://orcid.org/0000-0001-6080-8739)
- Dantin Jeramy Roddy
- Julia García Mancebo
- Yifeng Peng (ORCID: https://orcid.org/0000-0002-1273-8171)
- Salvador Carrasco Sosa
Institutions
- Boston Children's Hospital (US)
- Texas Children's Hospital (US)
Publication Details
- Journal
- Respiratory Care
- Published
- 2025-04-01
- DOI
- https://doi.org/10.4187/respcare.12371
- Citations
- 4
- Primary Topic
- Respiratory Support and Mechanisms
- Type
- article
- Field-Weighted Citation Impact
- 6.07