Initial experience of magnification tomosynthesis in depiction of suspected microcalcifications: prospective reading study of a novel reconstruction algorithm prototype

BackgroundDigital breast tomosynthesis (DBT) has several limitations with respect to microcalcification depiction. The quality of DBT images may be improved by modifying technical parameters; however, the amount of raw data and postprocessing computational time is unacceptably huge. Therefore, once detected it still seems necessary to take additional spot images to characterize microcalcifications. Additional imaging increases cumulative dose. Radiation risks and protection are raising issues nowadays.PurposeTo compare image quality of magnification tomosynthesis (t-spot) and synthetic spot magnification (s-spot) to conventional spot images in characterization of microcalcifications.Material and MethodsThis prospective single institute reading study includes 45 patients with suspected microcalcifications initially found on mammography and referred to vacuum-assisted biopsy. Conventional spot and DBT were performed. Acquired DBT data were used to reconstruct t- and s-spots. All images were reviewed by four breast radiologists in two sessions. The morphology (BI-RADS) and extent of microcalcifications were recorded. Clinical performance was evaluated using area under the receiver operating characteristic curves (AUC) for BI-RADS and Bland-Altman plots for the maximum extent of microcalcifications.ResultsAll four readers preferred t-spot to s-spot. The overall AUC for t-spot was 0.67 and for spot 0.69 with a difference lower than a non-inferiority margin (delta = 0.012, 95% confidence interval [CI] = -0.067-0.09, <i>P</i> = 0.772). Three readers underestimate the extent of microcalcifications on t-spots for both benign and malignant cases (<i>P</i> < 0.05). The discordance becomes more evident with the increasing extent of the lesion.ConclusionThe performance of conventional and reconstructed spots was similar but reader-dependent and inconclusive.

Authors

Institutions

Publication Details

Journal
Acta Radiologica
Published
2025-02-18
DOI
https://doi.org/10.1177/02841851251317633
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Initial experience of magnification tomosynthesis in depiction of suspected microcalcifications: prospective reading study of a novel reconstruction algorithm prototype

Kirill Arlan, Tuomo J Meretoja, Katja Hukkinen
1 links
Acta Radiologica
Digital Radiography and Breast Imaging
article

Initial experience of magnification tomosynthesis in depiction of suspected microcalcifications: prospective reading study of a novel reconstruction algorithm prototype

Kirill Arlan, Tuomo J Meretoja, Katja Hukkinen
article en

Abstract

BackgroundDigital breast tomosynthesis (DBT) has several limitations with respect to microcalcification depiction. The quality of DBT images may be improved by modifying technical parameters; however, the amount of raw data and postprocessing computational time is unacceptably huge. Therefore, once detected it still seems necessary to take additional spot images to characterize microcalcifications. Additional imaging increases cumulative dose. Radiation risks and protection are raising issues nowadays.PurposeTo compare image quality of magnification tomosynthesis (t-spot) and synthetic spot magnification (s-spot) to conventional spot images in characterization of microcalcifications.Material and MethodsThis prospective single institute reading study includes 45 patients with suspected microcalcifications initially found on mammography and referred to vacuum-assisted biopsy. Conventional spot and DBT were performed. Acquired DBT data were used to reconstruct t- and s-spots. All images were reviewed by four breast radiologists in two sessions. The morphology (BI-RADS) and extent of microcalcifications were recorded. Clinical performance was evaluated using area under the receiver operating characteristic curves (AUC) for BI-RADS and Bland-Altman plots for the maximum extent of microcalcifications.ResultsAll four readers preferred t-spot to s-spot. The overall AUC for t-spot was 0.67 and for spot 0.69 with a difference lower than a non-inferiority margin (delta = 0.012, 95% confidence interval [CI] = -0.067-0.09, <i>P</i> = 0.772). Three readers underestimate the extent of microcalcifications on t-spots for both benign and malignant cases (<i>P</i> < 0.05). The discordance becomes more evident with the increasing extent of the lesion.ConclusionThe performance of conventional and reconstructed spots was similar but reader-dependent and inconclusive.

Acta RadiologicaVol. 66(6)
University of Helsinki (FI), Helsinki University Hospital (FI)
Quality Education
Openalex Percentile: Top 95%
Digital Radiography and Breast Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.