Structural Analysis of Hydropower Stoplog: A Case Study of Seti Hydropower Project
Hydropower stoplogs are essential components in managing water flow within hydropower facilities, playing a critical role in ensuring safe operations and maintenance. Despite advancements in technology, existing designs face persistent challenges related to efficiency, environmental impact, and maintenance needs, highlighting a significant research gap in optimizing stoplog design. This study aims to address these issues by employing Finite Element Analysis (FEA) to evaluate stress distributions and material behavior in stoplog design, thereby enhancing overall performance. The methodology involved a comprehensive literature review, analytical design calculations, and the development of a detailed Computer-Aided Design (CAD) model, followed by iterative static structural analysis using ANSYS Mechanical. Key findings revealed that the integration of stiffeners and support systems significantly improved the stoplog's performance, achieving a maximum central deflection of 11.226 mm—just within the allowable limit of 11.25 mm—and a maximum stress of 241.18 MPa, well below permissible limits. These results confirm that the optimized stoplog design is both safe and efficient, illustrating the effectiveness of FEA in advancing hydropower infrastructure.
Authors
- Sagar Timilsina
- Paras Katuwal
Institutions
- Tribhuvan University (NP)
Publication Details
- Journal
- OODBODHAN
- Published
- 2024-12-31
- DOI
- https://doi.org/10.3126/oodbodhan.v7i1.75767
- Primary Topic
- Cavitation Phenomena in Pumps
- Type
- article
- Field-Weighted Citation Impact
- 0.00