Power Quality Enhancement Strategy In Grid Connected Dual Voltage Source Inverters Supplying Various Loads

This paper presents power quality improvement technique for grid connected dual inverter systems supplying non-linear and unbalanced loads. Control algorithms based on instantaneous symmetrical component theory (ISCT) are implemented in the dual voltage source inverter(DVSI). The DVSI enhance power quality by injecting real power and compensating for reactive, harmonic, and nonlinear loads. The dq0 transformation technique is utilized for effective voltage analysis at the Point of Common Coupling (PCC). Detailed simulation results validate the control strategy, demonstrating significant reduction in Total Harmonic Distortion (THD) and improved power quality. THD is analyzed for nonlinear and unbalanced load and reduced below 3%. The findings indicate that the DVSI scheme effectively mitigates harmonic problems, ensuring stable and reliable operation of interconnected grids, and complies with IEEE standards for THD and frequency maintenance.

Authors

Institutions

Publication Details

Journal
OODBODHAN
Published
2024-12-31
DOI
https://doi.org/10.3126/oodbodhan.v7i1.75761
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power Quality Enhancement Strategy In Grid Connected Dual Voltage Source Inverters Supplying Various Loads

Abinash Kshatri, Amrit Bhatta, Sandeep Dhami
OODBODHAN
Microgrid Control and Optimization
article

Power Quality Enhancement Strategy In Grid Connected Dual Voltage Source Inverters Supplying Various Loads

Abinash Kshatri, Amrit Bhatta, Sandeep Dhami
article en

Abstract

This paper presents power quality improvement technique for grid connected dual inverter systems supplying non-linear and unbalanced loads. Control algorithms based on instantaneous symmetrical component theory (ISCT) are implemented in the dual voltage source inverter(DVSI). The DVSI enhance power quality by injecting real power and compensating for reactive, harmonic, and nonlinear loads. The dq0 transformation technique is utilized for effective voltage analysis at the Point of Common Coupling (PCC). Detailed simulation results validate the control strategy, demonstrating significant reduction in Total Harmonic Distortion (THD) and improved power quality. THD is analyzed for nonlinear and unbalanced load and reduced below 3%. The findings indicate that the DVSI scheme effectively mitigates harmonic problems, ensuring stable and reliable operation of interconnected grids, and complies with IEEE standards for THD and frequency maintenance.

OODBODHANVol. 7
Tribhuvan University (NP)
Openalex Percentile: Top 66%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Power Quality Enhancement Strategy In Grid Connected Dual Voltage Source Inverters Supplying Various Loads — Abinash Kshatri, Amrit Bhatta, et al. · OODBODHAN (2024) | TGRS Research Map | TGRS