Multilayer perceptron approach for determining the centroid position of the electromagnetic shower in laterally segmented calorimeter

Abstract This paper presents a method employing a Multi-Layer Perceptron (MLP) neural network to enhance the spatial resolution of laterally segmented electromagnetic calorimeters. The study, based on GEANT4 simulations, explores the impact of different MLP architectures and hyperparameters on spatial resolution across a range of calorimeter block sizes and incident photon energies from 1 GeV to 10 GeV. Optimal configurations are identified, including the number of input neurons, hidden layers, and neurons per layer. The optimized MLP model consistently outperforms the widely used center of gravity method, achieving a significant improvement in spatial resolution that ranges from 8% for 1 GeV photons and a block size of half the Molière radius to 22% for 10 GeV photons and a block size of twice the Molière radius.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2025-02-01
DOI
https://doi.org/10.1088/1748-0221/20/02/t02006
Citations
2
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
3.77
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multilayer perceptron approach for determining the centroid position of the electromagnetic shower in laterally segmented calorimeter

W.I. Hamdi, M. Mazouz, Sahbi Chaibi
2 citations
Journal of Instrumentation
Radiation Detection and Scintillator Technologies
3.77
article

Multilayer perceptron approach for determining the centroid position of the electromagnetic shower in laterally segmented calorimeter

W.I. Hamdi, M. Mazouz, Sahbi Chaibi
article en
2 citations

Abstract

Abstract This paper presents a method employing a Multi-Layer Perceptron (MLP) neural network to enhance the spatial resolution of laterally segmented electromagnetic calorimeters. The study, based on GEANT4 simulations, explores the impact of different MLP architectures and hyperparameters on spatial resolution across a range of calorimeter block sizes and incident photon energies from 1 GeV to 10 GeV. Optimal configurations are identified, including the number of input neurons, hidden layers, and neurons per layer. The optimized MLP model consistently outperforms the widely used center of gravity method, achieving a significant improvement in spatial resolution that ranges from 8% for 1 GeV photons and a block size of half the Molière radius to 22% for 10 GeV photons and a block size of twice the Molière radius.

Journal of InstrumentationVol. 20(02)
University of Sfax (TN), University of Monastir (TN), National Engineering School of Tunis (TN)
Openalex Percentile: Top 9%
Radiation Detection and Scintillator Technologies
3.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.