Arc flash analysis using ETAP platform

Abstract Arc flash analysis during short circuit failure is an exciting issue that has significant implications for electrical design, management, maintenance, and operation of power systems. In this paper, a typical power system of a milk factory with voltage levels of 33kV, 11kV, and 0.4kV are considered for arc flash analysis on the platform of ETAP. The computation results show that the arc flash incident energies at some buses of the system are very high with the index of personal protective equipment (PPE) at the extreme danger level, and hence, the remedial procedure is inevitable. The two mitigation solutions of using low arc mode and arc flash detection relay are then verified. The latter strategy is demonstrated to be able to reduce the incident energy of arc flash at the dangerous buses to the level 2 of PPE, and hence, this method is recommended to apply for handling the arc flash hazard in this power system.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-02-01
DOI
https://doi.org/10.1088/1742-6596/2949/1/012019
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Arc flash analysis using ETAP platform

Thanh Tran Ngoc, Nam Nguyen Nhat
Journal of Physics Conference Series
Electrical Fault Detection and Protection
article

Arc flash analysis using ETAP platform

Thanh Tran Ngoc, Nam Nguyen Nhat
article en

Abstract

Abstract Arc flash analysis during short circuit failure is an exciting issue that has significant implications for electrical design, management, maintenance, and operation of power systems. In this paper, a typical power system of a milk factory with voltage levels of 33kV, 11kV, and 0.4kV are considered for arc flash analysis on the platform of ETAP. The computation results show that the arc flash incident energies at some buses of the system are very high with the index of personal protective equipment (PPE) at the extreme danger level, and hence, the remedial procedure is inevitable. The two mitigation solutions of using low arc mode and arc flash detection relay are then verified. The latter strategy is demonstrated to be able to reduce the incident energy of arc flash at the dangerous buses to the level 2 of PPE, and hence, this method is recommended to apply for handling the arc flash hazard in this power system.

Journal of Physics Conference SeriesVol. 2949(1)
University of Economics Ho Chi Minh City (VN), Ho Chi Minh City University of Technology (VN)
Openalex Percentile: Top 98%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.