Continuous Cuffless Non-Invasive Blood Pressure Detection from ECG and PPG Signals Using Artificial Neural Network

Hypertension, a primary cause of cardiovascular diseases (CVD), necessitates real-time and continuous blood pressure (BP) monitoring for accurate diagnosis and treatment. However, existing methods for continuous BP measurement are often invasive and painful, while non-invasive methods using cuffs lack convenience for continuous monitoring. This study proposes a continuous, non-invasive cuffless BP detection method using electrocardiogram (ECG) and photoplethysmogram (PPG) signals. By applying an Artificial Neural Network (ANN), we achieved accurate estimations of systolic (SBP) and diastolic (DBP) blood pressure. The model, developed with the MIMIC II database, demonstrated a Mean Absolute Error (MAE) of ±13.89 mmHg for SBP and ±5.5 mmHg for DBP. Comparisons with conventional methods showed an average error of 11.2 mmHg for SBP and 9.75 mmHg for DBP, validating its effectiveness for noninvasive, continuous BP monitoring without causing pain or risk of injury.

Authors

Institutions

Publication Details

Published
2024-11-19
DOI
https://doi.org/10.1109/cenim64038.2024.10882777
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Continuous Cuffless Non-Invasive Blood Pressure Detection from ECG and PPG Signals Using Artificial Neural Network

Muhammad Yazid, Rachmad Setiawan, Aushaf Cintya Wanda
Non-Invasive Vital Sign Monitoring
article

Continuous Cuffless Non-Invasive Blood Pressure Detection from ECG and PPG Signals Using Artificial Neural Network

Muhammad Yazid, Rachmad Setiawan, Aushaf Cintya Wanda
article en

Abstract

Hypertension, a primary cause of cardiovascular diseases (CVD), necessitates real-time and continuous blood pressure (BP) monitoring for accurate diagnosis and treatment. However, existing methods for continuous BP measurement are often invasive and painful, while non-invasive methods using cuffs lack convenience for continuous monitoring. This study proposes a continuous, non-invasive cuffless BP detection method using electrocardiogram (ECG) and photoplethysmogram (PPG) signals. By applying an Artificial Neural Network (ANN), we achieved accurate estimations of systolic (SBP) and diastolic (DBP) blood pressure. The model, developed with the MIMIC II database, demonstrated a Mean Absolute Error (MAE) of ±13.89 mmHg for SBP and ±5.5 mmHg for DBP. Comparisons with conventional methods showed an average error of 11.2 mmHg for SBP and 9.75 mmHg for DBP, validating its effectiveness for noninvasive, continuous BP monitoring without causing pain or risk of injury.

Sepuluh Nopember Institute of Technology (ID)
Zero hunger
Openalex Percentile: Top 75%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.