Enhanced Eleven Level (EEL) MLI with Lower Number of Switches and Voltage Stress Applied to Agriculture Motor

A single-phase, eleven-level asymmetrical inverter including three uneven DC sources, five bidirectional, and two unidirectional switches is recommended. Since it uses fewer switches to give more output voltage levels, the asymmetrical layout is recommended. Reducing THD without adding more switches or levels is the main objective of this endeavor. The best topology was found by conducting comparative analysis with earlier ones, and the load parameter design is described. Half height modulation and equal phase angle modulation are used as control strategies. A MATLAB/Simulink simulation of an EEL MLI asymmetrical inverter was performed. Here, several characteristics, In order to compare the THD obtained using the two methods, factors such as total standing voltage (TSV), cost function (CF), and power loss are investigated for both fundamental and developed EEL MLI.

Authors

Institutions

Publication Details

Published
2024-11-02
DOI
https://doi.org/10.1109/icissgt58904.2024.00023
Primary Topic
Advanced Machining and Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced Eleven Level (EEL) MLI with Lower Number of Switches and Voltage Stress Applied to Agriculture Motor

D Sivamani, D. Shyam, K. Premkumar, M. Priya et al.
Advanced Machining and Optimization Techniques
article

Enhanced Eleven Level (EEL) MLI with Lower Number of Switches and Voltage Stress Applied to Agriculture Motor

D Sivamani, D. Shyam, K. Premkumar, M. Priya, P Veeramanikandan, M.KALIY Amoorthy
article en

Abstract

A single-phase, eleven-level asymmetrical inverter including three uneven DC sources, five bidirectional, and two unidirectional switches is recommended. Since it uses fewer switches to give more output voltage levels, the asymmetrical layout is recommended. Reducing THD without adding more switches or levels is the main objective of this endeavor. The best topology was found by conducting comparative analysis with earlier ones, and the load parameter design is described. Half height modulation and equal phase angle modulation are used as control strategies. A MATLAB/Simulink simulation of an EEL MLI asymmetrical inverter was performed. Here, several characteristics, In order to compare the THD obtained using the two methods, factors such as total standing voltage (TSV), cost function (CF), and power loss are investigated for both fundamental and developed EEL MLI.

Dhanalakshmi Srinivasan Group of Institutions (IN), Rajalakshmi Engineering College
Zero hunger
Openalex Percentile: Top 75%
Advanced Machining and Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.