Protection strategy for ADN based on overcurrent relay with adaptability unit using local measurements

Traditional overcurrent protection strategies encounter significant challenges when implemented in active distribution networks (ADNs) owing to the dynamic operating modes and the variability of short-circuit levels of these electric systems. Consequently, adaptive protection mechanisms that operate autonomously are needed to ensure coordination and optimal response times in scenarios with high penetration of distributed energy resources (DERs). This paper introduces an adaptive protection strategy relying on local measurements. The approach utilises reference coordination to calculate a real-time adaptability coefficient, dynamically adjusting to the current system's operating mode. The proposed coefficient facilitates updating operating times in anticipation of potential faults. In addition, the proposed strategy amalgamates detection, directional computation, fault classification modules, the proposed adaptability mechanism, and the trip unit within a unified protective scheme. The proposed adaptive protection strategy is tested in a modified IEEE 34-bus test feeder, including synchronous and inverted-based DERs. Out of the 90 cases analysed, the strategy successfully adapts and maintains the expected relay operating times in 100% of instances, even with high fault resistance values. The previous results satisfy the protection requirements, in contrast to conventional protection strategies, which often present selectivity problems in the presence of DERs in connected and islanded operating modes. The considerable variation in short-circuit levels, a typical characteristic of ADNs, highlights the present strategy as a viable alternative for real-world application in distribution networks. • Use local measurements, avoiding communication links, which reduces costs and facilitates implementation in real systems. • Proposes an adaptive adjustment before the fault occurrence. • Ensures coordination regardless of operation mode, fault type and fault resistance value. • Allows online parameter updating with low computational burden using only local measurements. • Integrates adaptability, fault detection, fault direction calculation, fault classification and tripping units.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2025-02-20
DOI
https://doi.org/10.1016/j.rineng.2025.104410
Citations
4
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
4.86
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Protection strategy for ADN based on overcurrent relay with adaptability unit using local measurements

A. Herrera-Orozco, Juan José Mora Flórez, J. Cuero-Grueso
4 citations
Results in Engineering
Power Systems Fault Detection
4.86
article

Protection strategy for ADN based on overcurrent relay with adaptability unit using local measurements

A. Herrera-Orozco, Juan José Mora Flórez, J. Cuero-Grueso
article en
4 citations

Abstract

Traditional overcurrent protection strategies encounter significant challenges when implemented in active distribution networks (ADNs) owing to the dynamic operating modes and the variability of short-circuit levels of these electric systems. Consequently, adaptive protection mechanisms that operate autonomously are needed to ensure coordination and optimal response times in scenarios with high penetration of distributed energy resources (DERs). This paper introduces an adaptive protection strategy relying on local measurements. The approach utilises reference coordination to calculate a real-time adaptability coefficient, dynamically adjusting to the current system's operating mode. The proposed coefficient facilitates updating operating times in anticipation of potential faults. In addition, the proposed strategy amalgamates detection, directional computation, fault classification modules, the proposed adaptability mechanism, and the trip unit within a unified protective scheme. The proposed adaptive protection strategy is tested in a modified IEEE 34-bus test feeder, including synchronous and inverted-based DERs. Out of the 90 cases analysed, the strategy successfully adapts and maintains the expected relay operating times in 100% of instances, even with high fault resistance values. The previous results satisfy the protection requirements, in contrast to conventional protection strategies, which often present selectivity problems in the presence of DERs in connected and islanded operating modes. The considerable variation in short-circuit levels, a typical characteristic of ADNs, highlights the present strategy as a viable alternative for real-world application in distribution networks. • Use local measurements, avoiding communication links, which reduces costs and facilitates implementation in real systems. • Proposes an adaptive adjustment before the fault occurrence. • Ensures coordination regardless of operation mode, fault type and fault resistance value. • Allows online parameter updating with low computational burden using only local measurements. • Integrates adaptability, fault detection, fault direction calculation, fault classification and tripping units.

Results in EngineeringVol. 25
Technological University of Pereira (CO)
Openalex Percentile: Top 6%
Power Systems Fault Detection
4.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.